Multiplex Protein Profiling by Low-Signal-Loss Single-Cell Western Blotting with Fluorescent-Quenching Aptamers
Analytical Chemistry · 2023
DOI: 10.1021/acs.analchem.3c01577 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2023. Verfasst von Li Xu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Surgical Intensive Care Unit, Xinhua Hospital, School of Medicine and School of Biomedical Engineering, Shanghai Jia…. Hauptthemen laut MEDLINE: Aptamers, Nucleotide. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Shanghai Jiao Tong University, Ministry of Science and Technology of the People's Republic of China, Shanghai Municipal Education Commission.
Abstract (Originalsprache)
Single-cell western blotting (scWB) is a prevalent technique for high-resolution protein analysis on low-abundance cell samples. However, the extensive signal loss during repeated antibody stripping precludes multiplex protein detection. Herein, we introduce Fluorescent-quenching Aptamer-based Single-cell Western Blotting (FAS-WB) for multiplex protein detection at single-cell resolution. The minimal size of aptamer probes allows rapid in-gel penetration, diffusion, and elution. Meanwhile, the fluorophore-tagged aptamers, coordinated with complementary quenching strands, avoid the massive signal loss conventionally caused by antibody stripping during repeated staining. Such a strategy also facilitates multiplex protein analysis with a limited number of fluorescent tags. We demonstrated FAS-WB for co-imaging four biomarker proteins (EpCAM, PTK7, HER2, CA125) at single-cell resolution with lower signal loss and enhanced signal-to-noise ratio compared to conventional antibody-based scWB. Being more time-saving (less than 25 min per cycle) and economical (1/1000 cost of conventional antibody probes), FAS-WB offers a highly efficient platform for profiling multiplex proteins at single-cell resolution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Anesthesiology and Surgical Intensive Care Unit, Xinhua Hospital, School of Medicine and School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200230, China.
- State Key Laboratory of Oncogenes and Related Genes, Institute for Personalized Medicine, Shanghai Jiao Tong University, Shanghai 200230, China.
ORCID-Profile: Xianting Ding
Förderung
- Shanghai Jiao Tong University
- Ministry of Science and Technology of the People's Republic of China
- Shanghai Municipal Education Commission
- Science and Technology Commission of Shanghai Municipality
- Shanghai Clinical Research Center
- Shanghai Municipal Health Commission
- National Natural Science Foundation of China
- Shanghai Agriculture Applied Technology Development Program Project
Zitieren
APA
Xu, L., Xie, H., Wang, B., Zhu, Z., Jiang, H., Duan, X., Deng, S., Xu, J., Jiang, L., & Ding, X. (2023). Multiplex Protein Profiling by Low-Signal-Loss Single-Cell Western Blotting with Fluorescent-Quenching Aptamers. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.3c01577
Vancouver
Xu L, Xie H, Wang B, Zhu Z, Jiang H, Duan X, et al. Multiplex Protein Profiling by Low-Signal-Loss Single-Cell Western Blotting with Fluorescent-Quenching Aptamers. Analytical Chemistry. 2023. doi:10.1021/acs.analchem.3c01577
BibTeX
@article{Xu2023,
author = {Xu, Li and Xie, Haiyang and Wang, Boqian and Zhu, Zijian and Jiang, Hui and Duan, Xiaoqian and Deng, Shuxin and Xu, Jiasu and Jiang, Lai and Ding, Xianting},
title = {Multiplex Protein Profiling by Low-Signal-Loss Single-Cell Western Blotting with Fluorescent-Quenching Aptamers},
journal = {Analytical Chemistry},
year = {2023},
doi = {10.1021/acs.analchem.3c01577}
}
EUVIMED