Evaluating the Effect of Data Merging and Postacquisition Normalization on Statistical Analysis of Untargeted High-Resolution Mass Spectrometry Based Urinary Metabolomics Data
Analytical Chemistry · 09.01.2024 · 96 (1) · 33-40
DOI: 10.1021/acs.analchem.3c01380 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 19.12.2023. Verfasst von Fynn Brix und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Human Nutrition and Food Science, Kiel University, Kiel, Heinrich-Hecht-Platz 10, 24118 Kiel, Germany. Hauptthemen laut MEDLINE: Metabolomics. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Bundesministerium f?r Bildung und Forschung, Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Urine is one of the most widely used biofluids in metabolomic studies because it can be collected noninvasively and is available in large quantities. However, it shows large heterogeneity in sample concentration and consequently requires normalization to reduce unwanted variation and extract meaningful biological information. Biological samples like urine are commonly measured with electrospray ionization (ESI) coupled to a mass spectrometer, producing data sets for positive and negative modes. Combining these gives a more complete picture of the total metabolites present in a sample. However, the effect of this data merging on subsequent data analysis, especially in combination with normalization, has not yet been analyzed. To address this issue, we conducted a neutral comparison study to evaluate the performance of eight postacquisition normalization methods under different data merging procedures using 1029 urine samples from the Food Chain plus (FoCus) cohort. Samples were measured with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR-MS). Normalization methods were evaluated by five criteria capturing the ability to remove sample concentration variation and preserve relevant biological information. Merging data after normalization was generally favorable for quality control (QC) sample similarity, sample classification, and feature selection for most of the tested normalization methods. Merging data after normalization and the usage of probabilistic quotient normalization (PQN) in a similar setting are generally recommended. Relying on a single analyte to capture sample concentration differences, like with postacquisition creatinine normalization, seems to be a less preferable approach, especially when data merging is applied.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Institute of Human Nutrition and Food Science, Kiel University, Kiel, Heinrich-Hecht-Platz 10, 24118 Kiel, Germany.
- Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School, 30625 Hannover, Germany.
- Department of Internal Medicine I, University Medical Centre Schleswig-Holstein, Campus Kiel, 24105 Kiel, Germany.
- Institute of Clinical Molecular Biology, Kiel University and University Medical Center Schleswig-Holstein, Campus Kiel, 24105 Kiel, Germany.
- Institute of Medical Biometry and Statistics, University of Luebeck and Medical Centre Schleswig-Holstein, Campus Luebeck, 23562 Luebeck, Germany.
- Institute of Diabetes and Clinical Metabolic Research, Kiel University, Düsternbrooker Weg 17, 24105 Kiel, Germany.
ORCID-Profile: Fynn Brix
Förderung
- Bundesministerium f?r Bildung und Forschung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Brix, F., Demetrowitsch, T., Jensen-Kroll, J., Zacharias, H. U., Szymczak, S., Laudes, M., Schreiber, S., & Schwarz, K. (2024). Evaluating the Effect of Data Merging and Postacquisition Normalization on Statistical Analysis of Untargeted High-Resolution Mass Spectrometry Based Urinary Metabolomics Data. Analytical Chemistry, 96(1), 33-40. https://doi.org/10.1021/acs.analchem.3c01380
Vancouver
Brix F, Demetrowitsch T, Jensen-Kroll J, Zacharias HU, Szymczak S, Laudes M, et al. Evaluating the Effect of Data Merging and Postacquisition Normalization on Statistical Analysis of Untargeted High-Resolution Mass Spectrometry Based Urinary Metabolomics Data. Analytical Chemistry. 2024;96(1):33-40. doi:10.1021/acs.analchem.3c01380
BibTeX
@article{Brix2024,
author = {Brix, Fynn and Demetrowitsch, Tobias and Jensen-Kroll, Julia and Zacharias, Helena U and Szymczak, Silke and Laudes, Matthias and Schreiber, Stefan and Schwarz, Karin},
title = {Evaluating the Effect of Data Merging and Postacquisition Normalization on Statistical Analysis of Untargeted High-Resolution Mass Spectrometry Based Urinary Metabolomics Data},
journal = {Analytical Chemistry},
year = {2024},
volume = {96},
number = {1},
pages = {33--40},
doi = {10.1021/acs.analchem.3c01380}
}
EUVIMED