EUVIMEDEUVIMED entdecken
Open Access

Evaluation of the Orbitrap Ascend Tribrid Mass Spectrometer for Shotgun Proteomics

Yuchen He iD, Evgenia Shishkova iD, Trenton M Peters-Clarke iD, Dain R Brademan, Michael S Westphall, David Bergen, Jingjing Huang, Romain Huguet, Michael W Senko, Vlad Zabrouskov iD, Graeme C McAlister, Joshua J Coon iD

Analytical Chemistry · 18.07.2023 · 95 (28) · 10655-10663

DOI: 10.1021/acs.analchem.3c01155 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 30.06.2023. Verfasst von Yuchen He und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomolecular Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States. Hauptthemen laut MEDLINE: Proteomics, Proteins. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, NHGRI NIH HHS, National Institute of General Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mass spectrometry (MS)-based proteomics is a powerful technology to globally profile protein abundances, activities, interactions, and modifications. The extreme complexity of proteomics samples, which often contain hundreds of thousands of analytes, necessitates continuous development of MS techniques and instrumentation to improve speed, sensitivity, precision, and accuracy, among other analytical characteristics. Here, we systematically evaluated the Orbitrap Ascend Tribrid mass spectrometer in the context of shotgun proteomics, and we compared its performance to that of the previous generation of Tribrid instruments─the Orbitrap Eclipse. The updated architecture of the Orbitrap Ascend includes a second ion-routing multipole (IRM) in front of the redesigned C-trap/Orbitrap and a new ion funnel that allows gentler ion introduction, among other changes. These modifications in Ascend hardware configuration enabled an increase in parallelizable ion injection time during higher-energy collisional dissociation (HCD) Orbitrap tandem MS (FTMS2) analysis of ∼5 ms. This enhancement was particularly valuable in the analyses of limited sample amounts, where improvements in sensitivity resulted in up to 140% increase in the number of identified tryptic peptides. Further, analysis of phosphorylated peptides enriched from the K562 human cell line yielded up to ∼50% increase in the number of unique phosphopeptides and localized phosphosites. Strikingly, we also observed a ∼2-fold boost in the number of detected N-glycopeptides, likely owing to the improvements in ion transmission and sensitivity. In addition, we performed the multiplexed quantitative proteomics analyses of TMT11-plex labeled HEK293T tryptic peptides and observed 9-14% increase in the number of quantified peptides. In conclusion, the Orbitrap Ascend consistently outperformed its predecessor the Orbitrap Eclipse in various bottom-up proteomic analyses, and we anticipate that it will generate reproducible and in-depth datasets for numerous proteomic applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProteomicsProteinsHumansHEK293 CellsTandem Mass SpectrometryPhosphopeptides

Substanzen

ProteinsPhosphopeptides

Autor:innen und Institutionen

  • Department of Biomolecular Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States.
  • National Center for Quantitative Biology of Complex Systems, Madison, Wisconsin 53706, United States.
  • Department of Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States.
  • Morgridge Institute for Research, Madison, Wisconsin 53715, United States.
  • Thermo Fisher Scientific, San Jose, California 95134, United States.

ORCID-Profile: Yuchen He, Evgenia Shishkova, Trenton M Peters-Clarke, Vlad Zabrouskov, Joshua J Coon

Förderung

  • NIGMS NIH HHS
  • NHGRI NIH HHS
  • National Institute of General Medical Sciences

Zitieren

APA

He, Y., Shishkova, E., Peters-Clarke, T. M., Brademan, D. R., Westphall, M. S., Bergen, D., Huang, J., Huguet, R., Senko, M. W., Zabrouskov, V., McAlister, G. C., & Coon, J. J. (2023). Evaluation of the Orbitrap Ascend Tribrid Mass Spectrometer for Shotgun Proteomics. Analytical Chemistry, 95(28), 10655-10663. https://doi.org/10.1021/acs.analchem.3c01155

Vancouver

He Y, Shishkova E, Peters-Clarke TM, Brademan DR, Westphall MS, Bergen D, et al. Evaluation of the Orbitrap Ascend Tribrid Mass Spectrometer for Shotgun Proteomics. Analytical Chemistry. 2023;95(28):10655-10663. doi:10.1021/acs.analchem.3c01155

BibTeX
@article{He2023,
  author = {He, Yuchen and Shishkova, Evgenia and Peters-Clarke, Trenton M and Brademan, Dain R and Westphall, Michael S and Bergen, David and Huang, Jingjing and Huguet, Romain and Senko, Michael W and Zabrouskov, Vlad and McAlister, Graeme C and Coon, Joshua J},
  title = {Evaluation of the Orbitrap Ascend Tribrid Mass Spectrometer for Shotgun Proteomics},
  journal = {Analytical Chemistry},
  year = {2023},
  volume = {95},
  number = {28},
  pages = {10655--10663},
  doi = {10.1021/acs.analchem.3c01155}
}
Kostenlos starten →