Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 09.08.2023. Verfasst von Meng Du und 5 weiteren Autor:innen. Beteiligte Einrichtung: Chinese Academy of Sciences Key Laboratory of Urban Pollutant Conversion, Department of Environmental Science and Engineering, University of Science …. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China, Anhui Provincial Key Research and Development Plan.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Excitation-emission matrix (EEM) spectroscopy has been proven to be an effective tool for offline fluorescence analysis. However, the pretreatment of EEM data requires an additional ultraviolet-visible (UV-vis) absorption spectrum for inner filter effect (IFE) correction. This complicates the instrument structure and increases the test flow, thus hindering the practical application of EEM in environmental online monitoring. In this work, Rayleigh scattering in EEM, which is often masked, is leveraged to address this challenge as Rayleigh scattering light itself passes through the sample and experiences absorption. We establish a translation-corrected estimation by the Rayleigh scattering (TCERS) method to estimate absorbance, not only enabling the IFE self-correction of EEM but also providing orthogonal spectroscopy information. TCERS is hierarchically tested in real solutions, simulated turbid liquids, and various natural water samples. Results indicate that the predicted UV-vis absorption spectra have a cosine similarity of over 0.95 with the actual spectra. When using the predicted spectra to correct the IFE of EEM, only about 0.005/1.440 bits of information entropy are lost and the absolute errors in EEM are negligible. The proposed method has the potential to streamline the design of fluorescence spectrometers, making it possible to miniaturize, optimize, and popularize these instruments for various practical applications such as environmental monitoring.

Autor:innen und Institutionen

  • Chinese Academy of Sciences Key Laboratory of Urban Pollutant Conversion, Department of Environmental Science and Engineering, University of Science and Technology of China, Hefei 230026, China.
  • School of Metallurgy and Environment, Central South University, Changsha 410083, China.

ORCID-Profile: Wei Chen, Han-Qing Yu

Förderung

  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China
  • Anhui Provincial Key Research and Development Plan

Zitieren

APA

Du, M., Chen, W., Qian, C., Chen, Z., Chen, G. L., & Yu, H. Q. (2023). Using Rayleigh Scattering to Correct the Inner Filter Effect of the Fluorescence Excitation–Emission Matrix. Analytical Chemistry, 95(33), 12273-12283. https://doi.org/10.1021/acs.analchem.3c01093

Vancouver

Du M, Chen W, Qian C, Chen Z, Chen GL, Yu HQ. Using Rayleigh Scattering to Correct the Inner Filter Effect of the Fluorescence Excitation–Emission Matrix. Analytical Chemistry. 2023;95(33):12273-12283. doi:10.1021/acs.analchem.3c01093

BibTeX
@article{Du2023,
  author = {Du, Meng and Chen, Wei and Qian, Chen and Chen, Zhuo and Chen, Guan-Lin and Yu, Han-Qing},
  title = {Using Rayleigh Scattering to Correct the Inner Filter Effect of the Fluorescence Excitation–Emission Matrix},
  journal = {Analytical Chemistry},
  year = {2023},
  volume = {95},
  number = {33},
  pages = {12273--12283},
  doi = {10.1021/acs.analchem.3c01093}
}
Kostenlos starten →