Self-Powered Biosensor for a Highly Efficient and Ultrasensitive Dual-Biomarker Assay
Analytical Chemistry · 11.04.2023 · 95 (14) · 6046-6052
DOI: 10.1021/acs.analchem.3c00097 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 28.03.2023. Verfasst von Futing Wang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Molecular Science and Biomedicine Laboratory, State Key Laboratory for Chemo/Bio-Sensing and Chemometrics, College of Material Science and Engineerin…. Hauptthemen laut MEDLINE: Biosensing Techniques, MicroRNAs. Die Arbeit wurde bisher 52-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Natural Science Foundation of?Hunan Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
A dual-biomarker, self-powered biosensor was fabricated for the ultrasensitive detection of microRNA-21 (miRNA-21) and miRNA-155 based on enzymatic biofuel cells (EBFCs), catalytic hairpin assembly (CHA), and DNA hybridization chain reaction (HCR), with a capacitor and digital multimeter (DMM). In the presence of miRNA-21, the CHA and HCR are triggered and lead to the generation of a double-helix chain, which stimulates [Ru(NH3)6]3+ to move to the biocathode surface due to electrostatic interaction. Subsequently, the biocathode obtains electrons from the bioanode and reduces [Ru(NH3)6]3+ to [Ru(NH3)6]2+, which significantly increases the open-circuit voltage (E1OCV). When miRNA-155 is present, CHA and HCR cannot be completed, resulting in a low E2OCV. The self-powered biosensor allows for the simultaneous ultrasensitive detection of miRNA-21 and miRNA-155 with detection limits of 0.15 and 0.66 fM, respectively. Moreover, this self-powered biosensor exhibits the highly sensitive detection for miRNA-21 and miRNA-155 assay in human serum samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Molecular Science and Biomedicine Laboratory, State Key Laboratory for Chemo/Bio-Sensing and Chemometrics, College of Material Science and Engineering, College of Chemistry and Chemical Engineering, College of Biology,…
- The Cancer Hospital of the University of Chinese Academy of Sciences (Zhejiang Cancer Hospital), Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, Zhejiang 310022, China.
- Institute of Molecular Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, and College of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
ORCID-Profile: Ren Cai, Weihong Tan
Förderung
- Natural Science Foundation of?Hunan Province
- National Natural Science Foundation of China
Zitieren
APA
Wang, F., Cai, R., & Tan, W. (2023). Self-Powered Biosensor for a Highly Efficient and Ultrasensitive Dual-Biomarker Assay. Analytical Chemistry, 95(14), 6046-6052. https://doi.org/10.1021/acs.analchem.3c00097
Vancouver
Wang F, Cai R, Tan W. Self-Powered Biosensor for a Highly Efficient and Ultrasensitive Dual-Biomarker Assay. Analytical Chemistry. 2023;95(14):6046-6052. doi:10.1021/acs.analchem.3c00097
BibTeX
@article{Wang2023,
author = {Wang, Futing and Cai, Ren and Tan, Weihong},
title = {Self-Powered Biosensor for a Highly Efficient and Ultrasensitive Dual-Biomarker Assay},
journal = {Analytical Chemistry},
year = {2023},
volume = {95},
number = {14},
pages = {6046--6052},
doi = {10.1021/acs.analchem.3c00097}
}
EUVIMED