EUVIMEDEUVIMED entdecken
Crossref

Selective Aptamer Modification of Au Surfaces in a Microelectrode Sensor Array for Simultaneous Detection of Multiple Analytes

Debashis Sen iD, Robert A Lazenby iD

Analytical Chemistry · 02.05.2023 · 95 (17) · 6828-6835

DOI: 10.1021/acs.analchem.2c05335 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 18.04.2023. Verfasst von Debashis Sen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32306-4390, United States. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: Florida State University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aptamers have been employed as the biorecognition element in electrochemical aptamer-based (E-AB) biosensors, for the detection of a diverse range of analyte molecules, on electrodes with sizescales ranging from a few microns to several millimeters. Simultaneous detection of multiple different analytes requires the selective modification of multiple electrode surfaces with different aptamers. This process is typically achieved by incubating separate macroscale electrodes in a solution with the desired aptamer, which is unsuitable for microelectrode arrays in which the electrodes are closely spaced. In this work, we selectively modified electrode surfaces with thiolated aptamers of different single-stranded DNA sequences, by successive removal and addition of thiol monolayers. This was achieved by electrodesorption of thiol monolayers using controlled potential, to expose unmodified gold electrodes to be modified with a different thiolated aptamer, thus enabling multiple different aptamers to be used on the surfaces of closely spaced microelectrodes. All aptamers were methylene blue terminated, allowing redox currents to be measured and used to monitor aptamer probe packing density on the electrode surface and the selectivity of the sensors. Here, we demonstrate the microscale E-AB sensor multianalyte detection method using aptamers for target analytes, adenosine triphosphate, dopamine, and serotonin, which can ultimately be applied to perform localized simultaneous detection using electrode arrays.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideBiosensing TechniquesMicroelectrodesElectrodesOxidation-ReductionDNA, Single-StrandedGoldElectrochemical Techniques

Substanzen

Aptamers, NucleotideDNA, Single-StrandedGold

Autor:innen und Institutionen

  • Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32306-4390, United States.
  • Department of Chemistry, Faculty of Science, Comilla University, Cumilla 3506, Bangladesh.

ORCID-Profile: Debashis Sen, Robert A Lazenby

Förderung

  • Florida State University

Zitieren

APA

Sen, D., & Lazenby, R. A. (2023). Selective Aptamer Modification of Au Surfaces in a Microelectrode Sensor Array for Simultaneous Detection of Multiple Analytes. Analytical Chemistry, 95(17), 6828-6835. https://doi.org/10.1021/acs.analchem.2c05335

Vancouver

Sen D, Lazenby RA. Selective Aptamer Modification of Au Surfaces in a Microelectrode Sensor Array for Simultaneous Detection of Multiple Analytes. Analytical Chemistry. 2023;95(17):6828-6835. doi:10.1021/acs.analchem.2c05335

BibTeX
@article{Sen2023,
  author = {Sen, Debashis and Lazenby, Robert A},
  title = {Selective Aptamer Modification of Au Surfaces in a Microelectrode Sensor Array for Simultaneous Detection of Multiple Analytes},
  journal = {Analytical Chemistry},
  year = {2023},
  volume = {95},
  number = {17},
  pages = {6828--6835},
  doi = {10.1021/acs.analchem.2c05335}
}
Kostenlos starten →