Selective Aptamer Modification of Au Surfaces in a Microelectrode Sensor Array for Simultaneous Detection of Multiple Analytes
Analytical Chemistry · 02.05.2023 · 95 (17) · 6828-6835
DOI: 10.1021/acs.analchem.2c05335 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 18.04.2023. Verfasst von Debashis Sen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32306-4390, United States. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: Florida State University.
Abstract (Originalsprache)
Aptamers have been employed as the biorecognition element in electrochemical aptamer-based (E-AB) biosensors, for the detection of a diverse range of analyte molecules, on electrodes with sizescales ranging from a few microns to several millimeters. Simultaneous detection of multiple different analytes requires the selective modification of multiple electrode surfaces with different aptamers. This process is typically achieved by incubating separate macroscale electrodes in a solution with the desired aptamer, which is unsuitable for microelectrode arrays in which the electrodes are closely spaced. In this work, we selectively modified electrode surfaces with thiolated aptamers of different single-stranded DNA sequences, by successive removal and addition of thiol monolayers. This was achieved by electrodesorption of thiol monolayers using controlled potential, to expose unmodified gold electrodes to be modified with a different thiolated aptamer, thus enabling multiple different aptamers to be used on the surfaces of closely spaced microelectrodes. All aptamers were methylene blue terminated, allowing redox currents to be measured and used to monitor aptamer probe packing density on the electrode surface and the selectivity of the sensors. Here, we demonstrate the microscale E-AB sensor multianalyte detection method using aptamers for target analytes, adenosine triphosphate, dopamine, and serotonin, which can ultimately be applied to perform localized simultaneous detection using electrode arrays.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32306-4390, United States.
- Department of Chemistry, Faculty of Science, Comilla University, Cumilla 3506, Bangladesh.
ORCID-Profile: Debashis Sen, Robert A Lazenby
Förderung
- Florida State University
Zitieren
APA
Sen, D., & Lazenby, R. A. (2023). Selective Aptamer Modification of Au Surfaces in a Microelectrode Sensor Array for Simultaneous Detection of Multiple Analytes. Analytical Chemistry, 95(17), 6828-6835. https://doi.org/10.1021/acs.analchem.2c05335
Vancouver
Sen D, Lazenby RA. Selective Aptamer Modification of Au Surfaces in a Microelectrode Sensor Array for Simultaneous Detection of Multiple Analytes. Analytical Chemistry. 2023;95(17):6828-6835. doi:10.1021/acs.analchem.2c05335
BibTeX
@article{Sen2023,
author = {Sen, Debashis and Lazenby, Robert A},
title = {Selective Aptamer Modification of Au Surfaces in a Microelectrode Sensor Array for Simultaneous Detection of Multiple Analytes},
journal = {Analytical Chemistry},
year = {2023},
volume = {95},
number = {17},
pages = {6828--6835},
doi = {10.1021/acs.analchem.2c05335}
}
EUVIMED