EUVIMEDEUVIMED entdecken
Crossref

MnO 4 – -Triggered Immediate-Stable Real-Time Fluorescence Immunosensor with High Response Speed and Low Steady-State Error

Wenlin Ma, Lihua Pang, Jinhua Liu iD, Lei Wen, Huili Ma iD, Yinhui Li iD, Zhihui Xu, Chengwu Zhang, Hai-Dong Yu iD

Analytical Chemistry · 2023

DOI: 10.1021/acs.analchem.2c05149 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2023. Verfasst von Wenlin Ma und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), School of Flexible Electronics (Future Technologies), Nanji…. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Science and Technology Program of Hunan Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time chemical and biological sensing in vitro is important for application in health and environmental monitoring. Thus, a more rapid and stable detection method is urgently needed. Herein, an immediate-stable real-time fluorescent immunosensor with a high response speed (∼100%,

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesDopamineImmunoassayLimit of DetectionReaction TimeResorcinolsOxidesManganese Compounds

Substanzen

DopamineorcinolResorcinolspermanganic acidOxidesManganese Compounds

Autor:innen und Institutionen

  • Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), School of Flexible Electronics (Future Technologies), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816,…
  • Key Laboratory for Green Organic Synthesis and Application of Hunan Province, Key Laboratory of Environmentally Friendly Chemistry, Application of Ministry of Education, College of Chemistry, Xiangtan University, Xiangt…
  • Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University, 300 Guangzhou Road, Nanjing 210029, China.
  • School of Basic Medical Sciences, Shanxi Medical University, Xinjian Road, Taiyuan 310003, China.
  • Xi'an Institute of Flexible Electronics, Xi'an Key Laboratory of Flexible Electronics (KLoFE) & Xi'an Key Laboratory of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'…

ORCID-Profile: Jinhua Liu, Huili Ma, Yinhui Li, Hai-Dong Yu

Förderung

  • Science and Technology Program of Hunan Province
  • National Natural Science Foundation of China

Zitieren

APA

Ma, W., Pang, L., Liu, J., Wen, L., Ma, H., Li, Y., Xu, Z., Zhang, C., & Yu, H. D. (2023). MnO 4 – -Triggered Immediate-Stable Real-Time Fluorescence Immunosensor with High Response Speed and Low Steady-State Error. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.2c05149

Vancouver

Ma W, Pang L, Liu J, Wen L, Ma H, Li Y, et al. MnO 4 – -Triggered Immediate-Stable Real-Time Fluorescence Immunosensor with High Response Speed and Low Steady-State Error. Analytical Chemistry. 2023. doi:10.1021/acs.analchem.2c05149

BibTeX
@article{Ma2023,
  author = {Ma, Wenlin and Pang, Lihua and Liu, Jinhua and Wen, Lei and Ma, Huili and Li, Yinhui and Xu, Zhihui and Zhang, Chengwu and Yu, Hai-Dong},
  title = {MnO 4 – -Triggered Immediate-Stable Real-Time Fluorescence Immunosensor with High Response Speed and Low Steady-State Error},
  journal = {Analytical Chemistry},
  year = {2023},
  doi = {10.1021/acs.analchem.2c05149}
}
Kostenlos starten →