Significantly Enhanced Robustness of K Isotope Analysis by Collision Cell MC-ICP-MS and Its Application to the Returned Lunar Samples by China’s Chang’e-5 Project
Analytical Chemistry · 31.01.2023 · 95 (4) · 2140-2145
DOI: 10.1021/acs.analchem.2c03989 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 18.01.2023. Verfasst von Shichao An und 3 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory for Mineral Deposits Research, School of Earth Sciences and Engineering, Nanjing University, Nanjing, Jiangsu210023, P. R. China. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Central University Basic Research Fund of China, China National Space Administration, National Natural Science Foundation of China.
Abstract (Originalsprache)
Stable K isotope ratios, an emerging research tool for a wide range of problems, can be measured precisely with high sensitivity by using collision cell multicollector ICP mass spectrometers (CC-MC-ICP-MS). However, it has been shown that the accuracy of K isotope analysis by CC-MC-ICP-MS could be compromised severely by trace-level Ca contaminants, although the cause of such an effect remains poorly understood. Here, we report that the influence of Ca on K isotope analysis by CC-MC-ICP-MS can be dramatically reduced if D2 rather than H2 (the default gas) is used as the reaction gas that goes into the collision cell. This indicates the generation of positively charged calcium-hydride molecules in the collision cell. Usage of D2 as reaction gas circumvents the Ca-induced inaccuracy issues during K isotope analysis because 40CaD+ does not interfere with 41K+ as 40CaH+ does; as such, the robustness of K isotope analysis by CC-MC-ICP-MS is significantly enhanced. This improved method is verified by K isotope analysis of seven geostandards, and applied to China's Chang'e-5 lunar return samples at submicrogram K consumption, revealing significant K isotope variability within a 17 mg lunar basalt fragment.
Autor:innen und Institutionen
- State Key Laboratory for Mineral Deposits Research, School of Earth Sciences and Engineering, Nanjing University, Nanjing, Jiangsu210023, P. R. China.
- Frontiers Science Center for Critical Earth Material Cycling, Nanjing University, Nanjing210023, P. R. China.
ORCID-Profile: Weiqiang Li
Förderung
- Central University Basic Research Fund of China
- China National Space Administration
- National Natural Science Foundation of China
Zitieren
APA
An, S., Chen, J., Boschi, S., & Li, W. (2023). Significantly Enhanced Robustness of K Isotope Analysis by Collision Cell MC-ICP-MS and Its Application to the Returned Lunar Samples by China’s Chang’e-5 Project. Analytical Chemistry, 95(4), 2140-2145. https://doi.org/10.1021/acs.analchem.2c03989
Vancouver
An S, Chen J, Boschi S, Li W. Significantly Enhanced Robustness of K Isotope Analysis by Collision Cell MC-ICP-MS and Its Application to the Returned Lunar Samples by China’s Chang’e-5 Project. Analytical Chemistry. 2023;95(4):2140-2145. doi:10.1021/acs.analchem.2c03989
BibTeX
@article{An2023,
author = {An, Shichao and Chen, Jiayang and Boschi, Samuele and Li, Weiqiang},
title = {Significantly Enhanced Robustness of K Isotope Analysis by Collision Cell MC-ICP-MS and Its Application to the Returned Lunar Samples by China’s Chang’e-5 Project},
journal = {Analytical Chemistry},
year = {2023},
volume = {95},
number = {4},
pages = {2140--2145},
doi = {10.1021/acs.analchem.2c03989}
}