Wearable armband with a floating mobile exploratory electrode at fingertip for on-demand touch-and-measure multilead electrocardiography
Wearable Technologies · 2025 · 6
DOI: 10.1017/wtc.2025.11 ↗Kurz gefasst
Fachartikel in der Zeitschrift Wearable Technologies, online erschienen am 05.05.2025. Verfasst von Saygun Guler und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul, Türkiye. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bilim Akademisi, Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, Türkiye Bilimler Akademisi.
Abstract (Originalsprache)
Spurred by the global pandemic, research in health monitoring has pivoted towards the development of smart garments, enabling long-term tracking of individuals’ cardiovascular health by continuously monitoring the electrocardiogram (ECG) and detecting any abnormality in the signal morphology. Many types of dry electrodes have been proposed as alternatives to gold standard Ag/AgCl wet electrodes, and they have been integrated into clothes capable of acquiring only a limited number of the different ECG traces. This limitation severely diminishes the diagnostic utility of the collected ECG data and obstructs the garment’s potential for clinical-level evaluation. Here, we demonstrate a special ECG upper armband with a glove component which houses graphene-textile electrodes, where a fully mobile, exploring electrode located at the index finger enables the user to strategically position the electrode on-demand to desired body areas and measure the different ECG traces that are bipolar limb and unipolar chest leads. Based on measurements with and without employing the well-known Wilson Central Terminal (WCT) arrangement, the correlation ratio of unipolar ECG chest leads acquired with the graphene textile-based armband and Ag/AgCl electrodes both in “WCT-less” configuration reach up to %99.65; and up to %99.54 when Ag/AgCl electrodes are utilized “with WCT” while the graphene-based armband in “WCT-less” configuration. To the authors’ best knowledge, this study reports the first multilead on-demand “touch-and-measure” ECG recording from a fully wearable textile garment. Moreover, owing to the human-centered armband design, we achieved a more than three-fold reduction in electrode count from 10 in clinical ECG practice down to 3.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul, Türkiye.
- Department of Cardiology, Basaksehir Pine and Sakura City Hospital, Health Sciences University, Istanbul, Türkiye.
- (SUNUM) Nanotechnology Research and Application Center, Sabanci University, Istanbul, Türkiye.
- Department of Electrical and Computer Engineering, University of Washington, Seattle, WA, USA.
ORCID-Profile: Murat Kaya Yapici
Förderung
- Bilim Akademisi
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
- Türkiye Bilimler Akademisi
Zitieren
APA
Guler, S., Aslanger, E., & Yapici, M. K. (2025). Wearable armband with a floating mobile exploratory electrode at fingertip for on-demand touch-and-measure multilead electrocardiography. Wearable Technologies, 6. https://doi.org/10.1017/wtc.2025.11
Vancouver
Guler S, Aslanger E, Yapici MK. Wearable armband with a floating mobile exploratory electrode at fingertip for on-demand touch-and-measure multilead electrocardiography. Wearable Technologies. 2025;6. doi:10.1017/wtc.2025.11
BibTeX
@article{Guler2025,
author = {Guler, Saygun and Aslanger, Emre and Yapici, Murat Kaya},
title = {Wearable armband with a floating mobile exploratory electrode at fingertip for on-demand touch-and-measure multilead electrocardiography},
journal = {Wearable Technologies},
year = {2025},
volume = {6},
doi = {10.1017/wtc.2025.11}
}
EUVIMED