EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A wearable gait lab powered by sensor-driven digital twins for quantitative biomechanical analysis post-stroke

Donatella Simonetti iD, Maartje Hendriks, Bart Koopman, Noel Keijsers, Massimo Sartori

Wearable Technologies · 2024 · 5

DOI: 10.1017/wtc.2024.14 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Wearable Technologies, online erschienen am 14.11.2024. Verfasst von Donatella Simonetti und 4 weiteren Autor:innen. Beteiligte Einrichtung: Biomechanical Engineering Department, University of Twente, 7522 NB Enschede, Netherlands. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Commonly, quantitative gait analysis post-stroke is performed in fully equipped laboratories housing costly technologies for quantitative evaluation of a patient’s movement capacity. Combining such technologies with an electromyography (EMG)-driven musculoskeletal model can estimate muscle force properties non-invasively, offering clinicians insights into motor impairment mechanisms. However, lab-constrained areas and time-demanding sensor setup and data processing limit the practicality of these technologies in routine clinical care. We presented wearable technology featuring a multi-channel EMG-sensorized garment and an automated muscle localization technique. This allows unsupervised computation of muscle-specific activations, combined with five inertial measurement units (IMUs) for assessing joint kinematics and kinetics during various walking speeds. Finally, the wearable system was combined with a person-specific EMG-driven musculoskeletal model (referred to as human digital twins), enabling the quantitative assessment of movement capacity at a muscle-tendon level. This human digital twin facilitates the estimation of ankle dorsi-plantar flexion torque resulting from individual muscle-tendon forces. Results demonstrate the wearable technology’s capability to extract joint kinematics and kinetics. When combined with EMG signals to drive a musculoskeletal model, it yields reasonable estimates of ankle dorsi-plantar flexion torques ( R 2 = 0.65 ± 0.21) across different walking speeds for post-stroke individuals. Notably, EMG signals revealing an individual’s control strategy compensate for inaccuracies in IMU-derived kinetics and kinematics when input into a musculoskeletal model. Our proposed wearable technology holds promise for estimating muscle kinetics and resulting joint torque in time-limited and space-constrained environments. It represents a crucial step toward translating human movement biomechanics outside of controlled lab environments for effective motor impairment monitoring.

Schlagwörter

Stichwörter der Autor:innen

gaitkinematicskineticsmusculoskeletal modelwearable

Autor:innen und Institutionen

  • Biomechanical Engineering Department, University of Twente, 7522 NB Enschede, Netherlands.
  • Sint MaartensKlinik, 6574 NA Ubbergen, Netherlands.

ORCID-Profile: Donatella Simonetti

Zitieren

APA

Simonetti, D., Hendriks, M., Koopman, B., Keijsers, N., & Sartori, M. (2024). A wearable gait lab powered by sensor-driven digital twins for quantitative biomechanical analysis post-stroke. Wearable Technologies, 5. https://doi.org/10.1017/wtc.2024.14

Vancouver

Simonetti D, Hendriks M, Koopman B, Keijsers N, Sartori M. A wearable gait lab powered by sensor-driven digital twins for quantitative biomechanical analysis post-stroke. Wearable Technologies. 2024;5. doi:10.1017/wtc.2024.14

BibTeX
@article{Simonetti2024,
  author = {Simonetti, Donatella and Hendriks, Maartje and Koopman, Bart and Keijsers, Noel and Sartori, Massimo},
  title = {A wearable gait lab powered by sensor-driven digital twins for quantitative biomechanical analysis post-stroke},
  journal = {Wearable Technologies},
  year = {2024},
  volume = {5},
  doi = {10.1017/wtc.2024.14}
}
Kostenlos starten →