EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electromyography-based fatigue assessment of an upper body exoskeleton during automotive assembly

Jason C Gillette iD, Shekoofe Saadat, Terry Butler

Wearable Technologies · 2022 · 3

DOI: 10.1017/wtc.2022.20 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Wearable Technologies, online erschienen am 19.09.2022. Verfasst von Jason C Gillette und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kinesiology, Iowa State University, Ames, IA, USA. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The purpose of this study was to assess an upper body exoskeleton during automotive assembly processes that involve elevated arm postures. Sixteen team members at Toyota Motor Manufacturing Canada were fitted with a Levitate Airframe, and each team member performed between one and three processes with and without the exoskeleton. A total of 16 assembly processes were studied. Electromyography (EMG) data were collected on the anterior deltoid, biceps brachii, upper trapezius, and erector spinae. Team members also completed a usability survey. The exoskeleton significantly reduced anterior deltoid mean active EMG amplitude ( p = .01, Δ = −3.2 %MVC, d = 0.56 medium effect) and fatigue risk value ( p < .01, Δ = −5.1 %MVC, d = 0.62 medium effect) across the assembly processes, with no significant changes for the other muscles tested. A subset of nine assembly processes with a greater amount of time spent in arm elevations at or above 90° (30 vs. 24%) and at or above 135° (18 vs. 9%) appeared to benefit more from exoskeleton usage. For these processes, the exoskeleton significantly reduced anterior deltoid mean active EMG amplitude ( p < .01, Δ = −5.1 %MVC, d = 0.95 large effect) and fatigue risk value ( p < .01, Δ = −7.4 %MVC, d = 0.96 large effect). Team members responded positively about comfort and fatigue benefits, although there were concerns about the exoskeleton hindering certain job duties. The results support quantitative testing to match exoskeleton usage with specific job tasks and surveying team members for perceived benefits/drawbacks.

Schlagwörter

Stichwörter der Autor:innen

overhead workshoulderthreshold limit values

Autor:innen und Institutionen

  • Department of Kinesiology, Iowa State University, Ames, IA, USA.
  • Lean Steps Consulting Inc., West Des Moines, IA, USA.

ORCID-Profile: Jason C Gillette

Zitieren

APA

Gillette, J. C., Saadat, S., & Butler, T. (2022). Electromyography-based fatigue assessment of an upper body exoskeleton during automotive assembly. Wearable Technologies, 3. https://doi.org/10.1017/wtc.2022.20

Vancouver

Gillette JC, Saadat S, Butler T. Electromyography-based fatigue assessment of an upper body exoskeleton during automotive assembly. Wearable Technologies. 2022;3. doi:10.1017/wtc.2022.20

BibTeX
@article{Gillette2022,
  author = {Gillette, Jason C and Saadat, Shekoofe and Butler, Terry},
  title = {Electromyography-based fatigue assessment of an upper body exoskeleton during automotive assembly},
  journal = {Wearable Technologies},
  year = {2022},
  volume = {3},
  doi = {10.1017/wtc.2022.20}
}