EUVIMEDEUVIMED entdecken
Crossref

Dose volume histogram analysis for organs at risk when using 6 external beam techniques for radical prostatic irradiation

T. Haycocks, J. Mui, H. Alasti, C. Catton

Journal of Radiotherapy in Practice · 2000

DOI: 10.1017/s1460396900000042 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Radiotherapy in Practice, 2000. Verfasst von T. Haycocks und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ten patients with prostate cancer were each planned with 3 conventional and 3 conformal isocentric treatment techniques to compare the relative radiation doses to the bladder and rectal walls, and femoral head using dose volume histograms (DV H ). The DV H were calculated for each organ and each technique, and the plans were ranked using the area under the curve method and also by the relative radiation dose given to specific normal tissue volumes. The results show that for the planning target volume chosen, the 4 field non-coplanar technique delivers the least dose to the bladder, the 6 field coplanar technique delivers the least dose to the rectum and the 3 field oblique technique delivers the least dose to the femoral heads. The 4-field technique with no shielding contributes the most dose to the bladder and rectum and the 6 field coplanar technique contributes the most dose to the femoral heads. No technique was shown to be optimal for all the organs at risk, but both the 6 field and 4 field non-coplanar field arrangements were shown to be superior techniques for minimising both the bladder and rectal dosage. The choice of technique will therefore depend on other factors such as the total prescribed dose, the ease of set-up and the ease of verification of isocentre reproducibility.

Zitieren

APA

Haycocks, T., Mui, J., Alasti, H., & Catton, C. (2000). Dose volume histogram analysis for organs at risk when using 6 external beam techniques for radical prostatic irradiation. Journal of Radiotherapy in Practice. https://doi.org/10.1017/s1460396900000042

Vancouver

Haycocks T, Mui J, Alasti H, Catton C. Dose volume histogram analysis for organs at risk when using 6 external beam techniques for radical prostatic irradiation. Journal of Radiotherapy in Practice. 2000. doi:10.1017/s1460396900000042

BibTeX
@article{Haycocks2000,
  author = {Haycocks, T. and Mui, J. and Alasti, H. and Catton, C.},
  title = {Dose volume histogram analysis for organs at risk when using 6 external beam techniques for radical prostatic irradiation},
  journal = {Journal of Radiotherapy in Practice},
  year = {2000},
  doi = {10.1017/s1460396900000042}
}
Kostenlos starten →