EUVIMEDEUVIMED entdecken
Crossref

Mechanical haemolysis as a rare complication of modified Blalock–Thomas-Taussig shunt physiology

Wail Ali, Nayan Srivastava, Mark Rodefeld

Cardiology in the Young · 19.11.2026 · 1-4

DOI: 10.1017/s1047951126125086 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiology in the Young, online erschienen am 19.11.2026. Verfasst von Wail Ali und 2 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Mechanical haemolysis is a rare complication of modified Blalock–Thomas–Taussig shunt physiology. Abnormal shunt-related haemodynamics may generate pathologic shear forces resulting in clinically significant haemolysis, although this complication has been only rarely reported. Case presentation: A full-term infant with hypoplastic left heart syndrome underwent stage I Norwood palliation with placement of a 4.0-mm Gore-Tex modified Blalock–Thomas–Taussig shunt. The postoperative course was complicated by severe transfusion-dependent intravascular haemolysis, characterised by markedly elevated lactate dehydrogenase, plasma free haemoglobin, reticulocytosis, occasional schistocytes, and haemoglobinuria. A distinctive clinical feature was recurrent hypoxaemia that failed to improve with supplemental oxygen but consistently resolved following packed red blood cell transfusion. Extensive haematologic evaluation excluded alternative causes of haemolysis. Echocardiography demonstrated high-velocity flow across the shunt, while CT angiography revealed focal narrowing of the proximal innominate artery immediately proximal to the shunt origin, suggesting abnormal flow acceleration and increased shear stress. During the interstage period, the patient required 32 packed red blood cell transfusions. Following Hemi-Fontan completion with shunt takedown at 6 months of age, haemolysis resolved completely, and no further transfusions were required during hospitalisation or outpatient follow-up.

Conclusions

Proximal innominate artery narrowing associated with a modified Blalock–Thomas–Taussig shunt may exacerbate shunt-related shear stress, resulting in clinically significant mechanical haemolysis and recurrent transfusion-responsive hypoxaemia despite preserved shunt patency. Mechanical haemolysis should be considered in infants with unexplained transfusion-dependent anaemia following systemic-to-pulmonary shunt placement.

Zitieren

APA

Ali, W., Srivastava, N., & Rodefeld, M. (2026). Mechanical haemolysis as a rare complication of modified Blalock–Thomas-Taussig shunt physiology. Cardiology in the Young, 1-4. https://doi.org/10.1017/s1047951126125086

Vancouver

Ali W, Srivastava N, Rodefeld M. Mechanical haemolysis as a rare complication of modified Blalock–Thomas-Taussig shunt physiology. Cardiology in the Young. 2026:1-4. doi:10.1017/s1047951126125086

BibTeX
@article{Ali2026,
  author = {Ali, Wail and Srivastava, Nayan and Rodefeld, Mark},
  title = {Mechanical haemolysis as a rare complication of modified Blalock–Thomas-Taussig shunt physiology},
  journal = {Cardiology in the Young},
  year = {2026},
  pages = {1--4},
  doi = {10.1017/s1047951126125086}
}
Kostenlos starten →