EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing the impact of residual coarctation of the aorta on renal perfusion

Sigitas Cesna iD, Augustinas Bielinis, Tadas Zvirblis, Marius Miglinas, Virgilijus Tarutis

Cardiology in the Young · 2026-06 · 36 (6) · 1249-1255

DOI: 10.1017/s1047951126113663 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiology in the Young, online erschienen am 19.06.2026. Verfasst von Sigitas Cesna und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Clinical Medicine, Vilnius University Faculty of Medicine, Lithuania. Hauptthemen laut MEDLINE: Aortic Coarctation, Kidney, Hypertension, Renal Circulation. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Despite the effectiveness of the surgical or percutaneous treatment of coarctation of the aorta, the presence of hypertension in these patients remains a common and concerning issue. This study was undertaken to explore the relation between the severity of coarctation of the aorta and renal perfusion and to evaluate the role of renal scintigraphy as a predictive tool for clinical outcomes after percutaneous treatment of coarctation of the aorta.

Methods

Adult patients with coarctation of the aorta and concomitant arterial hypertension were enrolled in the study. Ambulatory 24-hour blood pressure monitoring, CT angiography, and a renal perfusion scan were performed, along with invasive pressure gradient measurements. Patients with invasive peak gradients ≥20mmHg and/or a difference of ≥50% in diameter between the isthmus and the descending aorta at the diaphragmatic level were selected for percutaneous stent implantation.

Results

The mean time to peak change in renal scintigraphy after captopril did not significantly differ between the Medical group (−1.01 ± 2.526 min. for the left kidney and −0.19 ± 1.46 min. for the right kidney) and the Stent group (−0.59 ± 1.188 min. for the left kidney and −0.17 ± 1.461 min. for the right kidney) ( p -values > 0.05). No statistically significant changes in renal perfusion were observed between pre-and post-stent implantation measurements.

Conclusion

In this pilot study, no clear association was found between the degree of aortic narrowing and renal perfusion, and no measurable reduction in renal perfusion was detected. Stent implantation did not result in significant short-term changes in blood pressure. These findings are exploratory and require confirmation in larger studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic CoarctationKidneyHypertensionRenal CirculationHumansFemaleMaleStentsAdultComputed Tomography AngiographyBlood Pressure Monitoring, AmbulatoryBlood PressureYoung AdultRadionuclide Imaging

Stichwörter der Autor:innen

coarctation of the aortapercutaneous treatmentrenal perfusionrenal scintigraphy scanresidual arterial hypertension

Autor:innen und Institutionen

  • Institute of Clinical Medicine, Vilnius University Faculty of Medicine, Lithuania.
  • Department of Interventional Cardiology, Vilnius University Hospital Santaros Klinikos, Lithuania.
  • Vilnius University Hospital Santaros Klinikos, Lithuania.
  • Department of Human and Medical Genetics, Institute of Biomedical sciences, Vilnius University Faculty of Medicine, Lithuania.
  • Institute of Data Science and Digital Technologies, Vilnius University Faculty of Mathematics and Informatics, Lithuania.
  • Centre of Cardiac Surgery, Vilnius University Hospital Santaros Klinikos, Lithuania.

ORCID-Profile: Sigitas Cesna

Zitieren

APA

Cesna, S., Bielinis, A., Zvirblis, T., Miglinas, M., & Tarutis, V. (2026). Assessing the impact of residual coarctation of the aorta on renal perfusion. Cardiology in the Young, 36(6), 1249-1255. https://doi.org/10.1017/s1047951126113663

Vancouver

Cesna S, Bielinis A, Zvirblis T, Miglinas M, Tarutis V. Assessing the impact of residual coarctation of the aorta on renal perfusion. Cardiology in the Young. 2026;36(6):1249-1255. doi:10.1017/s1047951126113663

BibTeX
@article{Cesna2026,
  author = {Cesna, Sigitas and Bielinis, Augustinas and Zvirblis, Tadas and Miglinas, Marius and Tarutis, Virgilijus},
  title = {Assessing the impact of residual coarctation of the aorta on renal perfusion},
  journal = {Cardiology in the Young},
  year = {2026},
  volume = {36},
  number = {6},
  pages = {1249--1255},
  doi = {10.1017/s1047951126113663}
}
Kostenlos starten →