Diagnostic accuracy of electrocardiographic parameters to detect left atrial enlargement in children with post-tricuspid left-to-right shunt

Rohan Ambali Parambil, Dheeraj Deo Bhatt, Sakshi Sachdeva iD, Dinesh Kumar Yadav, Amal Mohan

Cardiology in the Young · 2026-06 · 36 (6) · 1149-1156

DOI: 10.1017/s1047951126113602 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Cardiology in the Young, online erschienen am 23.06.2026. Verfasst von Rohan Ambali Parambil und 4 weiteren Autor:innen. Beteiligte Einrichtung: Pediatrics, Atal Bihari Vajpayee Institute of Medical Sciences & Dr Ram Manohar Lohia Hospital, India. Hauptthemen laut MEDLINE: Electrocardiography, Heart Atria, Cardiomegaly, Heart Septal Defects, Ventricular. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Left atrial enlargement is a surrogate marker for disease progression in congenital post-tricuspid left-to-right shunt lesions. Despite advanced imaging, a need persists for a more accessible modality like electrocardiography for early detection of left atrial enlargement. This study evaluates the diagnostic accuracy of established electrocardiography standards and a novel electrocardiography criterion (with altered position of chest leads) in identifying left atrial enlargement in children with post-tricuspid shunt lesions, enabling routine monitoring and timely referrals.

Methods

This cross-sectional observational study enrolled 227 children (1 month–18 years) with post-tricuspid shunts (ventricular septal defect, patent ductus arteriosus, and aortopulmonary window). Left atrial volume determined by 2D echocardiography was used as the reference standard to compare the diagnostic accuracy of electrocardiography parameters (negative P-terminal force at V1, P/PR segment, and bifid P wave) in detecting left atrial enlargement. The diagnostic accuracy of a novel method of measuring negative P-terminal force with lead V1 placed at the 2nd right intercostal space was compared with traditional electrocardiography parameters.

Results

Electrocardiography parameters showed diagnostic accuracy of 52.9–61.5%, sensitivity of 32.5–90.8%, and specificity of 17.8–89.7% for left atrial enlargement. Novel P-terminal force in V1 at the 2ndintercostal space (>151.2 mm.ms) had 32.5% sensitivity, 89.7% specificity, and 59.5% accuracy. At the 4th Rt. Intercostal space (novel P-terminal force in V1 ≥40 mm.ms), it had 74.2% sensitivity, 42.1% specificity, and 59.0% accuracy.

Conclusion

Measurement of the terminal negative force of the P wave at 2nd intercostal space has improved the specificity in the detection of left atrial enlargement. Future studies with higher sample sizes in a heterogeneous population might characterise this as a potential tool in detecting left atrial enlargement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyHeart AtriaCardiomegalyHeart Septal Defects, VentricularDuctus Arteriosus, PatentHumansInfantFemaleCross-Sectional StudiesChild, PreschoolMaleChildAdolescentEchocardiographySensitivity and Specificity

Stichwörter der Autor:innen

electrocardiographyleft atrial enlargementleft to right shunts

Autor:innen und Institutionen

  • Pediatrics, Atal Bihari Vajpayee Institute of Medical Sciences & Dr Ram Manohar Lohia Hospital, India.
  • Division of Pediatric Cardiology, Department of Pediatrics, Atal Bihari Vajpayee Institute of Medical Sciences & Dr Ram Manohar Lohia Hospital, India.

ORCID-Profile: Sakshi Sachdeva

Zitieren

APA

Parambil, R. A., Bhatt, D. D., Sachdeva, S., Yadav, D. K., & Mohan, A. (2026). Diagnostic accuracy of electrocardiographic parameters to detect left atrial enlargement in children with post-tricuspid left-to-right shunt. Cardiology in the Young, 36(6), 1149-1156. https://doi.org/10.1017/s1047951126113602

Vancouver

Parambil RA, Bhatt DD, Sachdeva S, Yadav DK, Mohan A. Diagnostic accuracy of electrocardiographic parameters to detect left atrial enlargement in children with post-tricuspid left-to-right shunt. Cardiology in the Young. 2026;36(6):1149-1156. doi:10.1017/s1047951126113602

BibTeX
@article{Parambil2026,
  author = {Parambil, Rohan Ambali and Bhatt, Dheeraj Deo and Sachdeva, Sakshi and Yadav, Dinesh Kumar and Mohan, Amal},
  title = {Diagnostic accuracy of electrocardiographic parameters to detect left atrial enlargement in children with post-tricuspid left-to-right shunt},
  journal = {Cardiology in the Young},
  year = {2026},
  volume = {36},
  number = {6},
  pages = {1149--1156},
  doi = {10.1017/s1047951126113602}
}
Kostenlos starten →