Device closure of residual aortopulmonary window using Konar-MF occluder device: an attractive new option
Cardiology in the Young · 2024
DOI: 10.1017/s1047951124025010 ↗Kurz gefasst
Fallbericht in der Zeitschrift Cardiology in the Young, 2024. Verfasst von Ahmad Usaid Qureshi und 2 weiteren Autor:innen. Beteiligte Einrichtung: The Children's Hospital, University of Child Health Sciences, Lahore, Pakistan. Hauptthemen laut MEDLINE: Aortopulmonary Septal Defect, Septal Occluder Device. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
We report a case of a residual aortopulmonary window where a new Konar-MF occluder device was used to close the defect. This device has a low profile and conforms to the anatomy of aortopulmonary window very nicely without unnecessary protrusion on either side. This report highlights the advantage of Konar-MF occluder device for closure of such defects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Children's Hospital, University of Child Health Sciences, Lahore, Pakistan.
ORCID-Profile: Ahmad Usaid Qureshi, Masood Sadiq
Zitieren
APA
Qureshi, A. U., Kazmi, T., & Sadiq, M. (2024). Device closure of residual aortopulmonary window using Konar-MF occluder device: an attractive new option. Cardiology in the Young. https://doi.org/10.1017/s1047951124025010
Vancouver
Qureshi AU, Kazmi T, Sadiq M. Device closure of residual aortopulmonary window using Konar-MF occluder device: an attractive new option. Cardiology in the Young. 2024. doi:10.1017/s1047951124025010
BibTeX
@article{Qureshi2024,
author = {Qureshi, Ahmad Usaid and Kazmi, Tehmina and Sadiq, Masood},
title = {Device closure of residual aortopulmonary window using Konar-MF occluder device: an attractive new option},
journal = {Cardiology in the Young},
year = {2024},
doi = {10.1017/s1047951124025010}
}
EUVIMED