EUVIMEDEUVIMED entdecken
Multizentrische StudieEvaluationsstudieOpen Access · CC BY 4.0

Effectiveness of the nucleus SmartNav system in detecting and preventing electrode tip fold-overs: a multi-centre retrospective analysis of 213 cochlear implantations

Mehmet Ekrem Zorlu iD, Emirhan Akyol, Secaattin Gülşen, Recep Karamert, Mehmet Birol Ugur, Hakan Tutar

The Journal of Laryngology & Otology · 2026

DOI: 10.1017/s0022215125104155 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift The Journal of Laryngology & Otology, 2026. Verfasst von Mehmet Ekrem Zorlu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology and Head & Neck Surgery, Gazi University Faculty of Medicinehttps://ror.org/054xkpr46, Ankara, Türkiye. Hauptthemen laut MEDLINE: Cochlear Implantation, Cochlea, Cochlear Implants. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to evaluate the effectiveness of the SmartNav in detecting tip fold-over during cochlear implantation and to compare angular insertion depth measurements obtained via SmartNav and transorbital X-ray imaging.

Methods

This retrospective multicentre study included patients with normal cochlear anatomy, comprising 163 individuals and 213 ears who underwent cochlear implantation using Nucleus CI522 and CI622 systems at Gazi University Faculty of Medicine and Gaziantep City Hospital.

Results

Of the 213 cochlear implantations, tip fold-over was detected in 4 implantations (1.88 per cent) intra-operatively with SmartNav. One case (0.47 per cent) of tip fold-over was not detected by SmartNav and identified post-operatively through X-ray imaging. SmartNav showed a sensitivity of 80 per cent, specificity of 100 per cent. A strong correlation was found between SmartNav and X-ray angular insertion depth measurements ( p < 0.001).

Conclusion

The SmartNav is a reliable tool for the intra-operative detection of tip fold-overand the assessment of angular insertion depth in patients with normal cochlear anatomy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantationCochleaCochlear ImplantsHumansRetrospective StudiesFemaleMaleChildChild, PreschoolAdultAdolescentMiddle AgedSensitivity and SpecificityElectrodes, ImplantedYoung AdultInfant

Stichwörter der Autor:innen

SmartNav systemX-raycochlear implantationhearing losstip fold-over

Autor:innen und Institutionen

  • Department of Otolaryngology and Head & Neck Surgery, Gazi University Faculty of Medicinehttps://ror.org/054xkpr46, Ankara, Türkiye.
  • Department of Otolaryngology and Head & Neck Surgery, Gaziantep City Hospital, Gaziantep, Türkiye.

ORCID-Profile: Mehmet Ekrem Zorlu

Zitieren

APA

Zorlu, M. E., Akyol, E., Gülşen, S., Karamert, R., Ugur, M. B., & Tutar, H. (2026). Effectiveness of the nucleus SmartNav system in detecting and preventing electrode tip fold-overs: a multi-centre retrospective analysis of 213 cochlear implantations. The Journal of Laryngology & Otology. https://doi.org/10.1017/s0022215125104155

Vancouver

Zorlu ME, Akyol E, Gülşen S, Karamert R, Ugur MB, Tutar H. Effectiveness of the nucleus SmartNav system in detecting and preventing electrode tip fold-overs: a multi-centre retrospective analysis of 213 cochlear implantations. The Journal of Laryngology & Otology. 2026. doi:10.1017/s0022215125104155

BibTeX
@article{Zorlu2026,
  author = {Zorlu, Mehmet Ekrem and Akyol, Emirhan and Gülşen, Secaattin and Karamert, Recep and Ugur, Mehmet Birol and Tutar, Hakan},
  title = {Effectiveness of the nucleus SmartNav system in detecting and preventing electrode tip fold-overs: a multi-centre retrospective analysis of 213 cochlear implantations},
  journal = {The Journal of Laryngology & Otology},
  year = {2026},
  doi = {10.1017/s0022215125104155}
}
Kostenlos starten →