EUVIMEDEUVIMED entdecken
Crossref

Immunoglobulin concentration in bovine colostrum obtained by indirect methods

Ingryd Muniz de Oliveira, Camila Soares Cunha, Luis Carlos Vinhas Ítavo iD, Luis Carlos Roma Júnior, Susana Amaral Teixeira, Geraldo Tadeu Dos Santos iD

Journal of Dairy Research · 2025

DOI: 10.1017/s0022029925101702 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Dairy Research, 2025. Verfasst von Ingryd Muniz de Oliveira und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Veterinary Medicine and Animal Science, Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil. Hauptthemen laut MEDLINE: Colostrum, Refractometry, Immunoglobulins, Immunoglobulin G. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The quality of colostrum is essential for the successful transfer of passive immunity and the early development of the immune system in newborns. This research was conducted with the aim of evaluating the agreement between measurements from different equipment: colostrometer, digital Brix refractometer and optical Brix refractometer, using fresh colostrum samples maintained at 21°C. Colostrum samples were collected from two farms ( n 1 = 31 and n 2 = 193). Farm 1 included females from second to ninth lactation, comprising 15 Holstein Friesian (HF), 5 Jersey and 11 Holstein × Jersey crossbreeds. Farm 2 had HF heifers and cows from first to seventh lactation. Immunoglobulin content was assessed indirectly with a colostrometer and both types of Brix refractometers (digital and optical). For the correlation analysis, Pearson's product-moment method was used to assess the linear association between the equipment, followed by a Student's t -test and comparison of the obtained values with specific correlation coefficients (50%, 70%, 90% and 99%). There was a 98% correlation between the refractometers on Farm 1, which was significantly higher ( P < 0.0001) than the commonly used reference values for weak (50%), moderate (70%) and strong (90%) correlations, and statistically equivalent to a 99% correlation. This indicates a very high, positive linear association between the digital and optical Brix refractometers. On Farm 2, a 97% correlation was found between the refractometers, which was significantly higher ( P < 0.0001) than the specific reference values of 50%, 70% and 90%, but significantly lower than a 99% correlation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColostrumRefractometryImmunoglobulinsImmunoglobulin GAnimalsCattleFemaleLactation

Stichwörter der Autor:innen

colostrumdairy cowsequipmentimmunological quality

Substanzen

ImmunoglobulinsImmunoglobulin G

Autor:innen und Institutionen

  • School of Veterinary Medicine and Animal Science, Universidade Federal de Mato Grosso do Sul, Campo Grande, MS, Brazil.
  • Agência Paulista de Tecnologia dos Agronegócios (APTA), Animal Science Institute, São Paulo, Brazil.

ORCID-Profile: Luis Carlos Vinhas Ítavo, Geraldo Tadeu Dos Santos

Zitieren

APA

de Oliveira, I. M., Cunha, C. S., Ítavo, L. C. V., Roma Júnior, L. C., Teixeira, S. A., & Dos Santos, G. T. (2025). Immunoglobulin concentration in bovine colostrum obtained by indirect methods. Journal of Dairy Research. https://doi.org/10.1017/s0022029925101702

Vancouver

de Oliveira IM, Cunha CS, Ítavo LCV, Roma Júnior LC, Teixeira SA, Dos Santos GT. Immunoglobulin concentration in bovine colostrum obtained by indirect methods. Journal of Dairy Research. 2025. doi:10.1017/s0022029925101702

BibTeX
@article{deOliveira2025,
  author = {de Oliveira, Ingryd Muniz and Cunha, Camila Soares and Ítavo, Luis Carlos Vinhas and Roma Júnior, Luis Carlos and Teixeira, Susana Amaral and Dos Santos, Geraldo Tadeu},
  title = {Immunoglobulin concentration in bovine colostrum obtained by indirect methods},
  journal = {Journal of Dairy Research},
  year = {2025},
  doi = {10.1017/s0022029925101702}
}
Kostenlos starten →