EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Transformation of aqueous protein attenuated total reflectance infra-red absorbance spectroscopy to transmission

Alison Rodger iD, Michael J Steel iD, Sophia C Goodchild iD, Nikola P Chmel iD, Andrew Reason

QRB Discovery · 2020 · 1

DOI: 10.1017/qrd.2020.11 ↗

Kurz gefasst

Fachartikel in der Zeitschrift QRB Discovery, online erschienen am 16.10.2020. Verfasst von Alison Rodger und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Molecular Sciences, Macquarie University, Sydney, NSW 2109, Australia. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Infrared (IR) spectroscopy is increasingly being used to probe the secondary structure of proteins, especially for high-concentration samples and biopharmaceuticals in complex formulation vehicles. However, the small path lengths required for aqueous protein transmission experiments, due to high water absorbance in the amide I region of the spectrum, means that the path length is not accurately known, so only the shape of the band is ever considered. This throws away a dimension of information. Attenuated total reflectance (ATR) IR spectroscopy is much easier to implement than transmission IR spectroscopy and, for a given instrument and sample, gives reproducible spectra. However, the ATR-absorbance spectrum varies with sample concentration and instrument configuration, and its wavenumber dependence differs significantly from that observed in transmission spectroscopy. In this paper, we determine, for the first time, how to transform water and aqueous protein ATR spectra into the corresponding transmission spectra with appropriate spectral shapes and intensities. The approach is illustrated by application to water, concanavalin A, haemoglobin and lysozyme. The transformation is only as good as the available water refractive index data. A hybrid of literature data provides the best results. The transformation also allows the angle of incidence of an ATR crystal to be determined. This opens the way to using both spectral shape and spectra intensity for protein structure fitting.

Schlagwörter

Stichwörter der Autor:innen

Attenuated total reflectanceinfrared spectroscopyproteinstructuretransmissionwater

Autor:innen und Institutionen

  • Department of Molecular Sciences, Macquarie University, Sydney, NSW 2109, Australia.
  • Department of Physics and Astronomy, Macquarie University, Sydney, NSW 2109, Australia.
  • Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK.
  • BioPharmaSpec Ltd., Lido Medical Centre, St. Saviour, Jersey JE2 7LA, UK.

ORCID-Profile: Alison Rodger, Michael J Steel, Sophia C Goodchild, Nikola P Chmel

Zitieren

APA

Rodger, A., Steel, M. J., Goodchild, S. C., Chmel, N. P., & Reason, A. (2020). Transformation of aqueous protein attenuated total reflectance infra-red absorbance spectroscopy to transmission. QRB Discovery, 1. https://doi.org/10.1017/qrd.2020.11

Vancouver

Rodger A, Steel MJ, Goodchild SC, Chmel NP, Reason A. Transformation of aqueous protein attenuated total reflectance infra-red absorbance spectroscopy to transmission. QRB Discovery. 2020;1. doi:10.1017/qrd.2020.11

BibTeX
@article{Rodger2020,
  author = {Rodger, Alison and Steel, Michael J and Goodchild, Sophia C and Chmel, Nikola P and Reason, Andrew},
  title = {Transformation of aqueous protein attenuated total reflectance infra-red absorbance spectroscopy to transmission},
  journal = {QRB Discovery},
  year = {2020},
  volume = {1},
  doi = {10.1017/qrd.2020.11}
}
Kostenlos starten →