Dynamic impedance is correlated with static impedance and seizure quality parameters in bifrontal electroconvulsive therapy
Acta Neuropsychiatrica · 2023
DOI: 10.1017/neu.2023.10 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Neuropsychiatrica, 2023. Verfasst von Jan Exner und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Psychiatry, Psychotherapy, and Psychosomatics, Psychiatric University Hospital of Zurich, University of Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Electroconvulsive Therapy. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
To evoke a therapeutically effective seizure, electrical stimulation in electroconvulsive therapy (ECT) has to overcome the combined resistivity of scalp, skull and other tissues. Static impedances are measured prior to stimulation using high-frequency electrical alternating pulses, dynamic impedances during passage of the stimulation current. Static impedance can partially be influenced by skin preparation techniques. Earlier studies showed a correlation between dynamic and static impedance in bitemporal and right unilateral ECT.
Objective
This study aims at assessing the correlation of dynamic and static impedance with patient characteristics and seizure quality criteria in bifrontal ECT Methods: We performed a cross-sectional single-centre retrospective analysis of ECT treatments at the Psychiatric University Hospital Zurich between May 2012 and March 2020 and used linear mixed-effects regression models in 78 patients with a total of 1757 ECT sessions.
Results
Dynamic and static impedance were strongly correlated. Dynamic impedance was significantly correlated with age and higher in women. Energy set and factors positively (caffeine) and negatively (propofol) affecting seizure at the neuronal level were not associated with dynamic impedance. For secondary outcomes, dynamic impedance was significantly related to Maximum Sustained Power and Average Seizure Energy Index. Other seizure quality criteria showed no significant correlation with dynamic impedance.
Conclusion
Aiming for low static impedance might reduce dynamic impedance, which is correlated with positive seizure quality parameters. Therefore, good skin preparation to achieve low static impedance is recommended.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Psychiatry, Psychotherapy, and Psychosomatics, Psychiatric University Hospital of Zurich, University of Zurich, Zurich, Switzerland.
- University Psychiatric Clinics, University of Basel, Basel, Switzerland.
ORCID-Profile: Jan Exner, Gunnar Deuring, Erich Seifritz, Annette Beatrix Brühl
Zitieren
APA
Exner, J., Deuring, G., Seifritz, E., & Brühl, A. B. (2023). Dynamic impedance is correlated with static impedance and seizure quality parameters in bifrontal electroconvulsive therapy. Acta Neuropsychiatrica. https://doi.org/10.1017/neu.2023.10
Vancouver
Exner J, Deuring G, Seifritz E, Brühl AB. Dynamic impedance is correlated with static impedance and seizure quality parameters in bifrontal electroconvulsive therapy. Acta Neuropsychiatrica. 2023. doi:10.1017/neu.2023.10
BibTeX
@article{Exner2023,
author = {Exner, Jan and Deuring, Gunnar and Seifritz, Erich and Brühl, Annette Beatrix},
title = {Dynamic impedance is correlated with static impedance and seizure quality parameters in bifrontal electroconvulsive therapy},
journal = {Acta Neuropsychiatrica},
year = {2023},
doi = {10.1017/neu.2023.10}
}
EUVIMED