EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Trends in body mass index and energy intake with and without biomarker calibration in the USA and Japanese National Nutrition Surveys

Yumiko Inoue, Daiki Watanabe iD, Motohiko Miyachi iD

Journal of Nutritional Science · 2026

DOI: 10.1017/jns.2025.10069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nutritional Science, 2026. Verfasst von Yumiko Inoue und 2 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Sport Sciences, Waseda University, Tokorozawa, Saitama, Japan. Hauptthemen laut MEDLINE: Body Mass Index, Energy Intake, Nutrition Surveys. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the USA and Japan, body mass index (BMI) has increased over the last several decades, whereas energy intake (EI) has decreased. However, self-reported EI data may show systematic errors. Using the calibration approach for attenuating the systematic error of self-reported EI, we aimed to compare trends in BMI and EI with and without calibration in adults from the USA and Japan. This cross-sectional study included 38,370 Americans evaluated in the National Health and Nutrition Examination Survey 2003–2018, and 200,629 Japanese evaluated in national nutrition surveys in Japan 1995–2019. EI was estimated using at least 1 day of 24-h diet recalls for Americans and 1 day of household-based dietary records for Japanese. The calibrated EI was calculated using a previously developed equation based on total energy expenditure (TEE) measured by doubly labelled water method. Using data from a review, uncalibrated EI was −20.2% and calibrated EI was −4.1% compared to the TEE; the calibration approach attenuated EI underestimation. In the USA, uncalibrated EI decreased (annual percentage change [APC]: −0.24%), but calibrated EI and BMI increased (calibrated EI, APC: 0.04%; BMI, APC: 0.32%). In Japan, the decrease was smaller for the calibrated EI than for the uncalibrated EI (uncalibrated EI, APC: −0.23%; calibrated EI, APC: −0.04%). Uncalibrated EI decreased and BMI increased in the USA and Japan, and calibrated EI increased in the USA and decreased slowly in Japan. Calibration may attenuate systematic bias in dietary assessments and facilitate the effective use of dietary data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Body Mass IndexEnergy IntakeNutrition SurveysAdultAgedFemaleHumansMaleMiddle AgedBiomarkersCalibrationCross-Sectional StudiesDietDiet RecordsEnergy MetabolismJapanUnited StatesNorth American PeopleEast Asian People

Stichwörter der Autor:innen

Calibration approachEnergy intakePhysical activitySelf-reported dietary Assessment

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Graduate School of Sport Sciences, Waseda University, Tokorozawa, Saitama, Japan.
  • National Institute of Biomedical Innovation, National Institutes of Biomedical Innovation, Health and Nutrition, Ibaraki, Osaka, Japan.
  • Faculty of Sport Sciences, Waseda University, Tokorozawa, Saitama, Japan.

ORCID-Profile: Daiki Watanabe, Motohiko Miyachi

Zitieren

APA

Inoue, Y., Watanabe, D., & Miyachi, M. (2026). Trends in body mass index and energy intake with and without biomarker calibration in the USA and Japanese National Nutrition Surveys. Journal of Nutritional Science. https://doi.org/10.1017/jns.2025.10069

Vancouver

Inoue Y, Watanabe D, Miyachi M. Trends in body mass index and energy intake with and without biomarker calibration in the USA and Japanese National Nutrition Surveys. Journal of Nutritional Science. 2026. doi:10.1017/jns.2025.10069

BibTeX
@article{Inoue2026,
  author = {Inoue, Yumiko and Watanabe, Daiki and Miyachi, Motohiko},
  title = {Trends in body mass index and energy intake with and without biomarker calibration in the USA and Japanese National Nutrition Surveys},
  journal = {Journal of Nutritional Science},
  year = {2026},
  doi = {10.1017/jns.2025.10069}
}
Kostenlos starten →