Evaluation of operating room high-touch surface cleaning effectiveness and process optimization based on dual-color fluorescent tracing technology
Infection Control & Hospital Epidemiology · 2026-11 · 47 (11) · 1177-1178
DOI: 10.1017/ice.2026.10518 ↗Kurz gefasst
Fachartikel in der Zeitschrift Infection Control & Hospital Epidemiology, online erschienen am 03.09.2026. Verfasst von Zhiqing Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Operating Room, Ganzhou Hospital-Nanfang Hospital, Southern Medical University (Ganzhou People's Hospital), Ganzhou, Jiangxi, China. Die Arbeit nennt 6 Literaturangaben.
Abstract (Originalsprache)
Visual inspection is highly subjective and cannot detect microscopic contamination. Microbiological culture methods have long turnaround times and delayed results, making them unsuitable for real-time guidance of cleaning activities. Although ATP bioluminescence assay can rapidly reflect organic contamination, its cost is high, and it cannot distinguish different cleaning stages such as routine cleaning versus terminal disinfection. 1,2 Fluorescent marker methods, as emerging semi-quantitative assessment tools, have been increasingly applied in health care environmental cleaning evaluation due to their speed, intuitiveness, and low cost. 3,4 However, existing studies predominantly use single-color marking. 3,4 Moreover, there is a lack of quantitative indicators for cleaning blind spots. To address these research gaps, this study proposes and applies dual-color fluorescent tracing technology with the cleaning blind-spot index (CBI) to precisely identify cleaning weaknesses and improve operating room cleaning quality. This prospective interventional study was conducted at a tertiary care hospital from October 2024 to April 2025. Ten Class III clean operating rooms were selected as study sites. The study comprised a 2-week baseline period followed by a 6-month intervention period. Seventeen high-touch surfaces were selected in each operating room based on previously published criteria, 2 – 5 including instrument cart rails, anesthesia machine control panels and buttons, operating table adjustment buttons, and infusion pump buttons. Medical-grade fluorescein sodium
Autor:innen und Institutionen
- Operating Room, Ganzhou Hospital-Nanfang Hospital, Southern Medical University (Ganzhou People's Hospital), Ganzhou, Jiangxi, China.
- Department of Medical and Pharmaceutical Technology, Heze Home Economics College, Heze, Shandong, China.
- Department of Clinical Laboratory, Ganzhou Hospital-Nanfang Hospital, Southern Medical University (Ganzhou People's Hospital), Ganzhou, Jiangxi, China.
ORCID-Profile: Dejun Xiao
Zitieren
APA
Liu, Z., Ge, H., Lan, H., Zeng, Y., Zhong, L., Cai, Y., & Xiao, D. (2026). Evaluation of operating room high-touch surface cleaning effectiveness and process optimization based on dual-color fluorescent tracing technology. Infection Control & Hospital Epidemiology, 47(11), 1177-1178. https://doi.org/10.1017/ice.2026.10518
Vancouver
Liu Z, Ge H, Lan H, Zeng Y, Zhong L, Cai Y, et al. Evaluation of operating room high-touch surface cleaning effectiveness and process optimization based on dual-color fluorescent tracing technology. Infection Control & Hospital Epidemiology. 2026;47(11):1177-1178. doi:10.1017/ice.2026.10518
BibTeX
@article{Liu2026,
author = {Liu, Zhiqing and Ge, Huimei and Lan, Haixia and Zeng, Yan and Zhong, Li and Cai, Yunxia and Xiao, Dejun},
title = {Evaluation of operating room high-touch surface cleaning effectiveness and process optimization based on dual-color fluorescent tracing technology},
journal = {Infection Control & Hospital Epidemiology},
year = {2026},
volume = {47},
number = {11},
pages = {1177--1178},
doi = {10.1017/ice.2026.10518}
}
EUVIMED