Impacts of indoor masks wearing on air contamination during 10-minute speaking in patients with SARS-CoV-2 omicron variant infection
Infection Control & Hospital Epidemiology · 2024
DOI: 10.1017/ice.2024.139 ↗Kurz gefasst
Fachartikel in der Zeitschrift Infection Control & Hospital Epidemiology, 2024. Verfasst von Se Yoon Park und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Infectious Diseases, Department of Internal Medicine, Hanyang University Seoul Hospital, Seoul, South Korea. Hauptthemen laut MEDLINE: COVID-19, SARS-CoV-2, N95 Respirators, Air Microbiology. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
In 10-minute speaking, N95 respirators significantly decreased SARS-CoV-2 emissions compared with no-mask wearing. However, SARS-CoV-2 was detected in the air even when wearing N95 and surgical masks in patients with high viral loads. Therefore, universal masking of infected and uninfected persons is important for preventing COVID-19 transmission via the air.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of Infectious Diseases, Department of Internal Medicine, Hanyang University Seoul Hospital, Seoul, South Korea.
- Division of Infectious Diseases, Department of Internal Medicine, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul, South Korea.
- Division of Infectious Diseases, Department of Internal Medicine, Chung-Ang University Hospital, Seoul, Republic of Korea.
- Division of Infectious Diseases, Department of Internal Medicine, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, South Korea.
- Department of Infectious Diseases, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
- Department of Architectural Engineering, Sejong University, Seoul, South Korea.
ORCID-Profile: Se Yoon Park, Min-Chul Kim, Minki Sung, Sung-Han Kim
Zitieren
APA
Park, S. Y., Kim, M. C., Kim, J. Y., Park, J. H., Bae, S., Chung, J. W., Yun, S., Sung, M., & Kim, S. H. (2024). Impacts of indoor masks wearing on air contamination during 10-minute speaking in patients with SARS-CoV-2 omicron variant infection. Infection Control & Hospital Epidemiology. https://doi.org/10.1017/ice.2024.139
Vancouver
Park SY, Kim MC, Kim JY, Park JH, Bae S, Chung JW, et al. Impacts of indoor masks wearing on air contamination during 10-minute speaking in patients with SARS-CoV-2 omicron variant infection. Infection Control & Hospital Epidemiology. 2024. doi:10.1017/ice.2024.139
BibTeX
@article{Park2024,
author = {Park, Se Yoon and Kim, Min-Chul and Kim, Ji Yeun and Park, Joung Ha and Bae, Seongman and Chung, Jin-Won and Yun, Saerom and Sung, Minki and Kim, Sung-Han},
title = {Impacts of indoor masks wearing on air contamination during 10-minute speaking in patients with SARS-CoV-2 omicron variant infection},
journal = {Infection Control & Hospital Epidemiology},
year = {2024},
doi = {10.1017/ice.2024.139}
}