Validation of the STERIS Amsco 630LS steam sterilizer autoclave for inactivation of category a medical waste from patients with high-consequence infectious diseases
Infection Control & Hospital Epidemiology · 2024-02 · 45 (2) · 260-262
DOI: 10.1017/ice.2023.188 ↗Kurz gefasst
Fachartikel in der Zeitschrift Infection Control & Hospital Epidemiology, online erschienen am 07.09.2023. Verfasst von Jessica A Tarabay und 3 weiteren Autor:innen. Beteiligte Einrichtung: Emory Healthcare, Atlanta, Georgia. Hauptthemen laut MEDLINE: Medical Waste, Communicable Diseases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Hospitals caring for patients with high-consequence pathogens may need to safely manage large volumes of category A waste. Using biological indicators to assess for successful sterilization, autoclave cycle parameters that would inactivate 4 categories of waste were identified and validated utilizing a STERIS Amsco 630LS Steam Sterilizer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Emory Healthcare, Atlanta, Georgia.
- Division of Infectious Diseases, Emory University School of Medicine, Atlanta, Georgia.
- Department of Pathology and Laboratory Medicine Emory University School of Medicine, Atlanta, Georgia.
ORCID-Profile: Jessica A Tarabay, Jill S Morgan, Colleen S Kraft, Mary Elizabeth Sexton
Zitieren
APA
Tarabay, J. A., Morgan, J. S., Kraft, C. S., & Sexton, M. E. (2024). Validation of the STERIS Amsco 630LS steam sterilizer autoclave for inactivation of category a medical waste from patients with high-consequence infectious diseases. Infection Control & Hospital Epidemiology, 45(2), 260-262. https://doi.org/10.1017/ice.2023.188
Vancouver
Tarabay JA, Morgan JS, Kraft CS, Sexton ME. Validation of the STERIS Amsco 630LS steam sterilizer autoclave for inactivation of category a medical waste from patients with high-consequence infectious diseases. Infection Control & Hospital Epidemiology. 2024;45(2):260-262. doi:10.1017/ice.2023.188
BibTeX
@article{Tarabay2024,
author = {Tarabay, Jessica A and Morgan, Jill S and Kraft, Colleen S and Sexton, Mary Elizabeth},
title = {Validation of the STERIS Amsco 630LS steam sterilizer autoclave for inactivation of category a medical waste from patients with high-consequence infectious diseases},
journal = {Infection Control & Hospital Epidemiology},
year = {2024},
volume = {45},
number = {2},
pages = {260--262},
doi = {10.1017/ice.2023.188}
}
EUVIMED