Comparison of virus aerosol concentrations across a face shield worn on a healthcare personnel during a simulated patient cough
Infection Control & Hospital Epidemiology · 2024
DOI: 10.1017/ice.2023.130 ↗Kurz gefasst
Fachartikel in der Zeitschrift Infection Control & Hospital Epidemiology, 2024. Verfasst von Alessandra A Pratt und 4 weiteren Autor:innen. Beteiligte Einrichtung: University of Iowa, Department of Occupational and Environmental Health, Iowa City, Iowa. Hauptthemen laut MEDLINE: SARS-CoV-2, COVID-19. Die Arbeit nennt 19 Literaturangaben.
Abstract (Originalsprache)
Background
Patients diagnosed with coronavirus disease 2019 (COVID-19) aerosolize severe acute respiratory coronavirus virus 2 (SARS-CoV-2) via respiratory efforts, expose, and possibly infect healthcare personnel (HCP). To prevent transmission of SARS-CoV-2 HCP have been required to wear personal protective equipment (PPE) during patient care. Early in the COVID-19 pandemic, face shields were used as an approach to control HCP exposure to SARS-CoV-2, including eye protection.
Methods
An MS2 bacteriophage was used as a surrogate for SARS-CoV-2 and was aerosolized using a coughing machine. A simulated HCP wearing a disposable plastic face shield was placed 0.41 m (16 inches) away from the coughing machine. The aerosolized virus was sampled using SKC biosamplers on the inside (near the mouth of the simulated HCP) and the outside of the face shield. The aerosolized virus collected by the SKC Biosampler was analyzed using a viability assay. Optical particle counters (OPCs) were placed next to the biosamplers to measure the particle concentration.
Results
There was a statistically significant reduction ( P < .0006) in viable virus concentration on the inside of the face shield compared to the outside of the face shield. The particle concentration was significantly lower on the inside of the face shield compared to the outside of the face shield for 12 of the 16 particle sizes measured ( P < .05).
Conclusions
Reductions in virus and particle concentrations were observed on the inside of the face shield; however, viable virus was measured on the inside of the face shield, in the breathing zone of the HCP. Therefore, other exposure control methods need to be used to prevent transmission from virus aerosol.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- University of Iowa, Department of Occupational and Environmental Health, Iowa City, Iowa.
- Iowa City Veterans Affairs Health Care System, Iowa City, Iowa.
- Department of Biostatistics, University of Iowa, Iowa City, Iowa.
- Department of Internal Medicine, Carver College of Medicine, University of Iowa, Iowa City, Iowa.
- Department of Medicine, Maine Medical Center, PortlandMaine.
- Department of Environmental, Agricultural and Occupational Health, University of Nebraska Medical Center, Omaha, Nebraska.
ORCID-Profile: Alessandra A Pratt, Grant D Brown
Zitieren
APA
Pratt, A. A., Brown, G. D., Perencevich, E. N., Diekema, D. J., & Nonnenmann, M. W. (2024). Comparison of virus aerosol concentrations across a face shield worn on a healthcare personnel during a simulated patient cough. Infection Control & Hospital Epidemiology. https://doi.org/10.1017/ice.2023.130
Vancouver
Pratt AA, Brown GD, Perencevich EN, Diekema DJ, Nonnenmann MW. Comparison of virus aerosol concentrations across a face shield worn on a healthcare personnel during a simulated patient cough. Infection Control & Hospital Epidemiology. 2024. doi:10.1017/ice.2023.130
BibTeX
@article{Pratt2024,
author = {Pratt, Alessandra A and Brown, Grant D and Perencevich, Eli N and Diekema, Daniel J and Nonnenmann, Matthew W},
title = {Comparison of virus aerosol concentrations across a face shield worn on a healthcare personnel during a simulated patient cough},
journal = {Infection Control & Hospital Epidemiology},
year = {2024},
doi = {10.1017/ice.2023.130}
}
EUVIMED