EUVIMEDEUVIMED entdecken
Crossref

A bronchoscopy-associated pseudo-outbreak of Mycobacterium chelonae and Mycobacterium mucogenicum associated with contaminated ice machine water and ice

Drew W Engers iD, Rajeev Swarup, Cheryl Morrin iD, Mica Blauw iD, Miles Selfridge, Pierre Gonyon, Janet E Stout, Anurag N Malani

Infection Control & Hospital Epidemiology · 2023

DOI: 10.1017/ice.2023.101 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Infection Control & Hospital Epidemiology, 2023. Verfasst von Drew W Engers und 7 weiteren Autor:innen. Beteiligte Einrichtung: Section of Infectious Diseases, Department of Medicine, Trinity Health Ann Arbor, Ann Arbor, Michigan. Hauptthemen laut MEDLINE: Bronchoscopy, Water Microbiology, Cross Infection, Mycobacterium Infections, Nontuberculous. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A pseudo-outbreak of bronchoscopy-associated Mycobacterium chelonae and M. mucogenicum was traced to contaminated ice machine water and ice. A nonsterile ice bath was used to cool uncapped, sterile, saline syringes used to slow procedural bleeding. Joining the growing evidence of bronchoscopy pseudo-outbreaks, our investigation describes several lessons for future prevention.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BronchoscopyWater MicrobiologyCross InfectionMycobacterium Infections, NontuberculousMycobacterium chelonaeMycobacteriaceaeHumansIceDisease Outbreaks

Substanzen

Ice

Autor:innen und Institutionen

  • Section of Infectious Diseases, Department of Medicine, Trinity Health Ann Arbor, Ann Arbor, Michigan.
  • Section of Pulmonary, Department of Medicine, Trinity Health Ann Arbor, Ann Arbor, Michigan.
  • Veterans' Affairs Hospital, Ann Arbor, Michigan.
  • Department of Infection Prevention and Control, Trinity Health Ann Arbor, Ann Arbor, Michigan.
  • Department of Infection Prevention and Control, Corewell Health. Grand Rapids, Michigan.
  • Department of Engineering, Trinity Health Ann Arbor, Ann Arbor, Michigan.

ORCID-Profile: Drew W Engers, Cheryl Morrin, Mica Blauw

Zitieren

APA

Engers, D. W., Swarup, R., Morrin, C., Blauw, M., Selfridge, M., Gonyon, P., Stout, J. E., & Malani, A. N. (2023). A bronchoscopy-associated pseudo-outbreak of Mycobacterium chelonae and Mycobacterium mucogenicum associated with contaminated ice machine water and ice. Infection Control & Hospital Epidemiology. https://doi.org/10.1017/ice.2023.101

Vancouver

Engers DW, Swarup R, Morrin C, Blauw M, Selfridge M, Gonyon P, et al. A bronchoscopy-associated pseudo-outbreak of Mycobacterium chelonae and Mycobacterium mucogenicum associated with contaminated ice machine water and ice. Infection Control & Hospital Epidemiology. 2023. doi:10.1017/ice.2023.101

BibTeX
@article{Engers2023,
  author = {Engers, Drew W and Swarup, Rajeev and Morrin, Cheryl and Blauw, Mica and Selfridge, Miles and Gonyon, Pierre and Stout, Janet E and Malani, Anurag N},
  title = {A bronchoscopy-associated pseudo-outbreak of Mycobacterium chelonae and Mycobacterium mucogenicum associated with contaminated ice machine water and ice},
  journal = {Infection Control & Hospital Epidemiology},
  year = {2023},
  doi = {10.1017/ice.2023.101}
}
Kostenlos starten →