EUVIMEDEUVIMED entdecken
Open Access

Using the Number of N95® Filtering Facepiece Respirator Models as an Indicator of Supply Chain Stability in a US Health-Care System

Alexa Furek, Mihili Edirisooriya, Megan Casey, Emily J Haas iD

Disaster Medicine and Public Health Preparedness · 2024

DOI: 10.1017/dmp.2024.9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Disaster Medicine and Public Health Preparedness, 2024. Verfasst von Alexa Furek und 3 weiteren Autor:innen. Beteiligte Einrichtung: National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Pittsburgh, PA, USA. Hauptthemen laut MEDLINE: Respiratory Protective Devices, Occupational Exposure. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Intramural CDC HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Personal protective equipment (PPE) supply chain disruptions force US health-care entities to adopt conservation strategies such as procurement from different respirator manufacturers. This research seeks to better understand how the number of respirator models on hand can serve as an indicator of N95 filtering facepiece respirator (FFR) supply chain stability or disruption.

Methods

Researchers looked at differences in the mean number of N95 FFR models, averaged weekly, from 10 hospitals in a health-care system over 15 wk from June 1 to September 10, 2020. Participating hospitals entered near-daily PPE inventory data by manufacturer and model number.

Results

A linear mixed effect model was run in SPSS v. 26 using a random intercept for hospitals, with week as a fixed predictor and mean number of respirator models (averaged weekly) on hand as the dependent variable. Each week showed a small but significant effect compared with the past week ( P < 0.001), where the average weekly number of respirator models on hand decreased.

Conclusions

The limited data may indicate a resolution of supply chain disruptions and warrant further investigation. Consequently, the number of respirator models may be applicable as an indicator of supply chain stability and be more easily ascertained and tracked by health-care entities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Respiratory Protective DevicesOccupational ExposureHumansVentilators, MechanicalN95 RespiratorsPersonal Protective Equipment

Stichwörter der Autor:innen

N95 respiratoremergency preparednessoccupational healthrespiratory protective devicesupply chain

Autor:innen und Institutionen

  • National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Pittsburgh, PA, USA.
  • National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Morgantown, WV, USA.

ORCID-Profile: Emily J Haas

Förderung

  • Intramural CDC HHS

Zitieren

APA

Furek, A., Edirisooriya, M., Casey, M., & Haas, E. J. (2024). Using the Number of N95® Filtering Facepiece Respirator Models as an Indicator of Supply Chain Stability in a US Health-Care System. Disaster Medicine and Public Health Preparedness. https://doi.org/10.1017/dmp.2024.9

Vancouver

Furek A, Edirisooriya M, Casey M, Haas EJ. Using the Number of N95® Filtering Facepiece Respirator Models as an Indicator of Supply Chain Stability in a US Health-Care System. Disaster Medicine and Public Health Preparedness. 2024. doi:10.1017/dmp.2024.9

BibTeX
@article{Furek2024,
  author = {Furek, Alexa and Edirisooriya, Mihili and Casey, Megan and Haas, Emily J},
  title = {Using the Number of N95® Filtering Facepiece Respirator Models as an Indicator of Supply Chain Stability in a US Health-Care System},
  journal = {Disaster Medicine and Public Health Preparedness},
  year = {2024},
  doi = {10.1017/dmp.2024.9}
}
Kostenlos starten →