EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

OpenLimbTT, a transtibial residual limb shape model for prosthetics simulation and design: creating a statistical anatomic model using sparse data

Fiona Sunderland, Adam Sobey, Jennifer Bramley, Joshua Steer, Rami Al-Dirini, Cheryl Metcalf, Diana Toderita, Anthony Bull, Ziyun Ding, David Henson, Peter Worsley, Alex Dickinson

Data-Centric Engineering · 2025 · 6

DOI: 10.1017/dce.2025.10019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Data-Centric Engineering, online erschienen am 15.08.2025. Verfasst von Fiona Sunderland und 11 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal Academy of Engineering, Eurostars, Royal British Legion.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Poor socket fit is the leading cause of prosthetic limb discomfort. However, currently clinicians have limited objective data to support and improve socket design. Finite element analysis predictions might help improve the fit, but this requires internal and external anatomy models. While external 3D surface scans are often collected in routine clinical computer-aided design practice, detailed internal anatomy imaging (e.g., MRI or CT) is not. We present a prototype statistical shape model (SSM) describing the transtibial amputated residual limb, generated using a sparse dataset of 33 MRI and CT scans. To describe the maximal shape variance, training scans are size-normalized to their estimated intact tibia length. A mean limb is calculated and principal component analysis used to extract the principal modes of shape variation. In an illustrative use case, the model is interrogated to predict internal bone shapes given a skin surface shape. The model attributes ~52% of shape variance to amputation height and ~17% to slender-bulbous soft tissue profile. In cross-validation, left-out shapes influenced the mean by 0.14–0.88 mm root mean square error (RMSE) surface deviation (median 0.42 mm), and left-out shapes were recreated with 1.82–5.75 mm RMSE (median 3.40 mm). Linear regression between mode scores from skin-only- and full-model SSMs allowed prediction of bone shapes from the skin with 3.56–10.9 mm RMSE (median 6.66 mm). The model showed the feasibility of predicting bone shapes from surface scans, which addresses a key barrier to implementing simulation within clinical practice, and enables more representative prosthetic biomechanics research.

Förderung

  • Royal Academy of Engineering
  • Eurostars
  • Royal British Legion
  • Engineering and Physical Sciences Research Council

Zitieren

APA

Sunderland, F., Sobey, A., Bramley, J., Steer, J., Al-Dirini, R., Metcalf, C., Toderita, D., Bull, A., Ding, Z., Henson, D., Worsley, P., & Dickinson, A. (2025). OpenLimbTT, a transtibial residual limb shape model for prosthetics simulation and design: creating a statistical anatomic model using sparse data. Data-Centric Engineering, 6. https://doi.org/10.1017/dce.2025.10019

Vancouver

Sunderland F, Sobey A, Bramley J, Steer J, Al-Dirini R, Metcalf C, et al. OpenLimbTT, a transtibial residual limb shape model for prosthetics simulation and design: creating a statistical anatomic model using sparse data. Data-Centric Engineering. 2025;6. doi:10.1017/dce.2025.10019

BibTeX
@article{Sunderland2025,
  author = {Sunderland, Fiona and Sobey, Adam and Bramley, Jennifer and Steer, Joshua and Al-Dirini, Rami and Metcalf, Cheryl and Toderita, Diana and Bull, Anthony and Ding, Ziyun and Henson, David and Worsley, Peter and Dickinson, Alex},
  title = {OpenLimbTT, a transtibial residual limb shape model for prosthetics simulation and design: creating a statistical anatomic model using sparse data},
  journal = {Data-Centric Engineering},
  year = {2025},
  volume = {6},
  doi = {10.1017/dce.2025.10019}
}
Kostenlos starten →