Incorporating SARS-CoV-2 Case Surveillance Data in the Comparison of Wastewater Concentration Methods for Wastewater Surveillance
Antimicrobial Stewardship & Healthcare Epidemiology · 2026-08 · 6 (S1) · s187-s188
DOI: 10.1017/ash.2026.10732 ↗Kurz gefasst
Fachartikel in der Zeitschrift Antimicrobial Stewardship & Healthcare Epidemiology, online erschienen am 23.06.2026. Verfasst von Florence Whitehill und 15 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Healthcare facility-level wastewater surveillance (WWS) is a relatively novel tool for pathogen surveillance. The most sensitive methods for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in wastewater remain unknown. In this study at skilled nursing facilities (SNFs), two wastewater concentration methods were evaluated for SARS-CoV-2 detection by droplet digital polymerase chain reaction (ddPCR): Electronegative membrane filtration (enMF) and Nanotrap® Magnetic Virus Particles (NP). SARS-CoV-2 case surveillance data from the SNFs was incorporated into this evaluation.
Methods
Wastewater samples were collected weekly from manholes at three SNFs over 25 weeks in 2022. Samples were split and concentrated by both enMF and NP, then virus concentration was determined by ddPCR. We utilized a weekly questionnaire and each facility’s National Healthcare Safety Network COVID-19 Report to identify the number of resident and healthcare personnel cases in each facility. Differences in the median SARS-CoV-2 concentration were compared across the enMF and NP methods using the Wilcoxon signed-rank test (?=0.05). Spearman’s correlation (?) was used to evaluate the relationship between the SARS-CoV-2 concentration in wastewater and SARS-CoV-2 case counts.
Results
For each facility separately, as well as overall, median virus concentration in wastewater from enMF was higher than that from NP (SNF A: 2.84 vs. 1.49 genome copies [gc]/100 mL; SNF B: 8.50 vs. 6.08 gc/100 mL; SNF C: 5.3 vs. 3.86 gc/100 mL; overall: 5.3 vs. 3.86 gc/100 mL). The Wilcoxon signed-rank test confirmed that the difference in median virus concentrations was statistically significant for SNF B (p=0.001) and overall (p=0.001). Spearman’s correlation results showed overall higher correlations with enMF than with NP and a greater number of statistically significant results among subpopulations. For example: using enMF, the correlation among residents and healthcare personnel combined at SNF A was ?=0.86 (p=
Zitieren
APA
Whitehill, F., Lyons, A., Abera, B., Adler, C., Burgos-Garay, M., Campbell, M., Moore, J., Santiago, A. J., Ganim, C., Cahela, Y., Lenz, S., Gable, P., Medrzycki, M., Walters, M., Keaton, A., & Coulliette-Salmond, A. (2026). Incorporating SARS-CoV-2 Case Surveillance Data in the Comparison of Wastewater Concentration Methods for Wastewater Surveillance. Antimicrobial Stewardship & Healthcare Epidemiology, 6(S1), s187-s188. https://doi.org/10.1017/ash.2026.10732
Vancouver
Whitehill F, Lyons A, Abera B, Adler C, Burgos-Garay M, Campbell M, et al. Incorporating SARS-CoV-2 Case Surveillance Data in the Comparison of Wastewater Concentration Methods for Wastewater Surveillance. Antimicrobial Stewardship & Healthcare Epidemiology. 2026;6(S1):s187-s188. doi:10.1017/ash.2026.10732
BibTeX
@article{Whitehill2026,
author = {Whitehill, Florence and Lyons, Amanda and Abera, Bethelhem and Adler, Colin and Burgos-Garay, Maria and Campbell, Mariya and Moore, Jamari and Santiago, Ariel J. and Ganim, Christine and Cahela, Yimu and Lenz, Susanna and Gable, Paige and Medrzycki, Magdalena and Walters, Maroya and Keaton, Amelia and Coulliette-Salmond, Angela},
title = {Incorporating SARS-CoV-2 Case Surveillance Data in the Comparison of Wastewater Concentration Methods for Wastewater Surveillance},
journal = {Antimicrobial Stewardship & Healthcare Epidemiology},
year = {2026},
volume = {6},
number = {S1},
pages = {s187--s188},
doi = {10.1017/ash.2026.10732}
}
EUVIMED