An accessible, absorbance-based plate reader assay to assess cumulative exposure of blood plasma & serum to thawed conditions
Methods · 2026-10 · 254 · 123-135
DOI: 10.1016/j.ymeth.2026.07.001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Methods, 2026-10. Verfasst von Nilojan Jehanathan und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Molecular Sciences, Arizona State University, Tempe, AZ 85287, USA; The Biodesign Institute at Arizona State University, Tempe, AZ 85287, U…. Hauptthemen laut MEDLINE: Sulfhydryl Compounds, Serum, Plasma. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Institutes of Health, National Institutes of Health National Cancer Institute.
Abstract (Originalsprache)
The integrity of human plasma and serum (P&S) is crucial for reliable biomarker discovery and validation, but it is affected by preanalytical exposure to thawed conditions (temperatures > -30 °C). The limited number of existing quality control methods for assessing plasma or serum (P/S) integrity often require resource-intensive techniques like mass spectrometry. We have developed and validated an accessible, cost-effective absorbance-based plate reader assay based on the oxidative ex vivo consumption of most small molecule thiols & disulfides (SMT&D) by albumin. The assay separates SMT&D from proteins, then uses tris(2-carboxyethyl)phosphine to reduce SMT&D, with subsequent quenching by 4-azidobenzoic acid, followed by reaction of thiols with Ellman's reagent. The method was optimized for yield, including steps to remove trace metals and minimize thiol re-oxidation. Due to inter-individual matrix effects, it was determined that measurements of each specimen before and after intentional expiration (which produce a single Δ-absorbance value, calibrated to Δ-SMT&D) are required to forensically evaluate prior exposure to thawed conditions. The assay demonstrated robust linearity, precision, and accuracy across diverse inter-individual matrices. Stability assessments at 23 °C, 4 °C and -20 °C revealed consistent exponential decay patterns in SMT&D, similar to those observed in the established LC/MS-based ΔS-Cys-Albumin assay. Estimated population reference ranges for P&S demonstrated sufficient dynamic range for the analysis of single samples with unknown histories. This potential was verified with blinded challenges. The assay provides a practical, readily accessible tool for quantifying P&S exposure to thawed conditions, facilitating improved quality control for investigators working with P&S for clinical or research purposes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Molecular Sciences, Arizona State University, Tempe, AZ 85287, USA; The Biodesign Institute at Arizona State University, Tempe, AZ 85287, USA; GenScript, Piscataway, NJ 08854, USA(1).
- School of Molecular Sciences, Arizona State University, Tempe, AZ 85287, USA; The Biodesign Institute at Arizona State University, Tempe, AZ 85287, USA.
- School of Molecular Sciences, Arizona State University, Tempe, AZ 85287, USA; The Biodesign Institute at Arizona State University, Tempe, AZ 85287, USA. Electronic address: chad.borges@asu.edu.
Förderung
- NCI NIH HHS
- National Institutes of Health
- National Institutes of Health National Cancer Institute
Zitieren
APA
Jehanathan, N., Quansah, I. A., Kremer, S., Kapuruge, E. P., & Borges, C. R. (2026). An accessible, absorbance-based plate reader assay to assess cumulative exposure of blood plasma & serum to thawed conditions. Methods, 254, 123-135. https://doi.org/10.1016/j.ymeth.2026.07.001
Vancouver
Jehanathan N, Quansah IA, Kremer S, Kapuruge EP, Borges CR. An accessible, absorbance-based plate reader assay to assess cumulative exposure of blood plasma & serum to thawed conditions. Methods. 2026;254:123-135. doi:10.1016/j.ymeth.2026.07.001
BibTeX
@article{Jehanathan2026,
author = {Jehanathan, Nilojan and Quansah, Ishmael A and Kremer, Schuyler and Kapuruge, Erandi P and Borges, Chad R},
title = {An accessible, absorbance-based plate reader assay to assess cumulative exposure of blood plasma & serum to thawed conditions},
journal = {Methods},
year = {2026},
volume = {254},
pages = {123--135},
doi = {10.1016/j.ymeth.2026.07.001}
}
EUVIMED