The influence of structured light scanning probe configuration on the 3D scanning accuracy of the maxillofacial region in a smiling state: An in vitro study

Miaosheng Guan, Xiaoyu Wang, Xue Li, Yaqi Wang, Kun Yan, Ran Huo, Tao Song, Lin Liu, Hongbo Li

Methods · 2025

DOI: 10.1016/j.ymeth.2025.05.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Methods, 2025. Verfasst von Miaosheng Guan und 8 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Smiling, Face. Die Arbeit nennt 46 Literaturangaben. Gefördert von: Chinese PLA General Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Currently, single-unit, dual-unit, and triple-unit structured light 3D scanning technologies have become the predominant facial scanning methods. However, the impact of different unit strategies on facial scanning accuracy remains unclear. A standardized 3D facial model in a smiling state was established. Key point reference coordinates and 3D data were obtained using a coordinate measurement instrument and an industrial-grade laser 3D scanner. Three structured light scanning techniques (single-, dual-, triple-unit) were utilized to capture the 3D information of the model. Linear distance deviations and 3D surface deviations (trueness and precision) of the three scanning strategies were compared. The triple-unit scanning strategy exhibited the lowest deviation among 20 trueness indicators and 22 precision indicators for linear distance measurements (P < 0.05). Furthermore, the accuracy of the triple-unit strategy (trueness: 0.1607 ± 0.0201 mm, precision: 0.0161 ± 0.0112 mm) for overall facial scanning was significantly lower than that of the single-unit and dual-unit strategies, particularly in critical regions for oral and maxillofacial aesthetic analysis, such as the orbital, nasal, and perioral regions. The triple-unit structured light scanning strategy significantly enhances the accuracy of facial 3D scanning, particularly when acquiring 3D facial information from the midline and perioral regions. This in vitro study demonstrates that the triple-unit structured light 3D scanning strategy effectively improves the accuracy of facial scanning, especially in the oral-maxillofacial aesthetic regions. This approach provides a foundation and support for both preoperative planning and postoperative evaluation of aesthetic restoration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalSmilingFaceHumansLasersModels, Anatomic

Stichwörter der Autor:innen

Digital dentistrySmiling stateStructured lightThree-dimensional scanning

Autor:innen und Institutionen

  • The Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China.
  • The Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China; The Department of Stomatology, The Ninth Medical Center, Chinese PLA General Hospital, Beijing 100101, China.
  • The College of Computer Science and Technology, China University of Petroleum (East China), Qingdao 266580, China.
  • The Department of Stomatology, PLA 80th Group Army Hospital, Weifang 261000, China.
  • The College of Computer Science and Technology, China University of Petroleum (East China), Qingdao 266580, China. Electronic address: tsong@upc.edu.cn.
  • The Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China. Electronic address: liulin768@163.com.

Förderung

  • Chinese PLA General Hospital

Zitieren

APA

Guan, M., Wang, X., Li, X., Wang, Y., Yan, K., Huo, R., Song, T., Liu, L., & Li, H. (2025). The influence of structured light scanning probe configuration on the 3D scanning accuracy of the maxillofacial region in a smiling state: An in vitro study. Methods. https://doi.org/10.1016/j.ymeth.2025.05.006

Vancouver

Guan M, Wang X, Li X, Wang Y, Yan K, Huo R, et al. The influence of structured light scanning probe configuration on the 3D scanning accuracy of the maxillofacial region in a smiling state: An in vitro study. Methods. 2025. doi:10.1016/j.ymeth.2025.05.006

BibTeX
@article{Guan2025,
  author = {Guan, Miaosheng and Wang, Xiaoyu and Li, Xue and Wang, Yaqi and Yan, Kun and Huo, Ran and Song, Tao and Liu, Lin and Li, Hongbo},
  title = {The influence of structured light scanning probe configuration on the 3D scanning accuracy of the maxillofacial region in a smiling state: An in vitro study},
  journal = {Methods},
  year = {2025},
  doi = {10.1016/j.ymeth.2025.05.006}
}
Kostenlos starten →