EUVIMEDEUVIMED entdecken
Crossref

Microplate fluorescence quenching for high throughput screening of affinity constants – Serum albumins and zearalenones case study

Heiðar Már Aðalsteinsson, Lavínia Quartin Pinto, Tatiana Q Aguiar, José A Teixeira, Luís Abrunhosa

Methods · 2025

DOI: 10.1016/j.ymeth.2024.12.011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Methods, 2025. Verfasst von Heiðar Már Aðalsteinsson und 4 weiteren Autor:innen. Beteiligte Einrichtung: CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal. Electronic address: heidar.adalst@ceb.uminho.pt. Hauptthemen laut MEDLINE: Serum Albumin, Zearalenone, High-Throughput Screening Assays. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Foundation for Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Measurements of changes in fluorescence signal is one of the most commonly applied methods for studying protein-ligand affinities. These measurements are generally carried out using cuvettes in spectrofluorometers, which can only measure one sample at a time. This makes screening procedures for multiple ligands and proteins extremely laborious, as each protein must be measured with multiple ligand concentrations, and usually in triplicate. Moreover, multiple equations exist to extract the affinity constants and other information from the data, and their underlying assumptions are often disregarded. In this study, the affinities of human, bovine and rat serum albumins for the mycotoxin zearalenone and five of its common derivatives were measured in 96-well microplates, allowing quick measurements of multiple samples using less reagent amounts. In comparison to measurements using a cuvette in a spectrofluorometer, the microplate method was shown to reproduce the affinity constants accurately. The results were discussed in terms of common pitfalls regarding experimental setup and available equations to analyze protein-ligand binding in fluorescence quenching assays. The commonly used Stern-Volmer equation was discussed in detail and the results used to show how inaccurate it is when a fluorescent protein-ligand complex is formed, and when other underlying approximations are ignored.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Serum AlbuminZearalenoneHigh-Throughput Screening AssaysAnimalsHumansRatsSpectrometry, FluorescenceCattleProtein BindingLigandsSerum Albumin, Bovine

Stichwörter der Autor:innen

Fluorescence quenchingMycotoxinsProtein-ligand affinitySerum albuminsZearalenone

Substanzen

Serum AlbuminZearalenoneLigandsSerum Albumin, Bovine

Autor:innen und Institutionen

  • CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal. Electronic address: heidar.adalst@ceb.uminho.pt.
  • CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal.
  • CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal; LABBELS - Associate Laboratory, University of Minho, Braga/Guimarães, Portugal.
  • CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal; LABBELS - Associate Laboratory, University of Minho, Braga/Guimarães, Portugal. Electronic address: luisjap@ceb.uminho.pt.

Förderung

  • Foundation for Science and Technology

Zitieren

APA

Aðalsteinsson, H. M., Quartin Pinto, L., Aguiar, T. Q., Teixeira, J. A., & Abrunhosa, L. (2025). Microplate fluorescence quenching for high throughput screening of affinity constants – Serum albumins and zearalenones case study. Methods. https://doi.org/10.1016/j.ymeth.2024.12.011

Vancouver

Aðalsteinsson HM, Quartin Pinto L, Aguiar TQ, Teixeira JA, Abrunhosa L. Microplate fluorescence quenching for high throughput screening of affinity constants – Serum albumins and zearalenones case study. Methods. 2025. doi:10.1016/j.ymeth.2024.12.011

BibTeX
@article{Aalsteinsson2025,
  author = {Aðalsteinsson, Heiðar Már and Quartin Pinto, Lavínia and Aguiar, Tatiana Q and Teixeira, José A and Abrunhosa, Luís},
  title = {Microplate fluorescence quenching for high throughput screening of affinity constants – Serum albumins and zearalenones case study},
  journal = {Methods},
  year = {2025},
  doi = {10.1016/j.ymeth.2024.12.011}
}
Kostenlos starten →