EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY-NC-ND 4.0

Validation of plasmonic-based biosensors for rapid and in depth characterization of monoclonal antibodies directed against rabbit haemorrhagic and foot-and-mouth disease viruses in biological samples

Chiara Urbinati, Giulia Pezzoni, Patrizia Cavadini, Vittoria Di Giovanni, Lorenzo Capucci, Marco Rusnati

Methods · 2025

DOI: 10.1016/j.ymeth.2024.12.003 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Methods, 2025. Verfasst von Chiara Urbinati und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Molecular and Translational Medicine, University of Brescia, Brescia, Italy. Hauptthemen laut MEDLINE: Surface Plasmon Resonance, Hemorrhagic Disease Virus, Rabbit, Foot-and-Mouth Disease Virus, Antibodies, Monoclonal. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministero dell’Istruzione, dell’Università e della Ricerca, Ministry of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

ELISA and RT-PCR represent the standard tools for the sensitive identification of viruses in biological samples, but they lack the capacity to finely characterize the binding of viruses or viral antigens to monoclonal antibodies (MAbs). Biosensing technologies are gaining increasing importance as powerful MAb characterization tools in the field of virology. Surface plasmon resonance (SPR) is an optical biosensing technology already used for the in depth characterization of MAbs of diagnostic and therapeutic value. Rabbit haemorrhagic disease virus (RHDV) and foot-and-mouth disease virus (FMDV) are top veterinary issues for which the development of novel methods aimed at the characterization of antiviral MAbs represents a priority with important livestock healthcare and economic implications. With these premises in mind, here we prepared a series of SPR biosensors by immobilizing RHDV2 or its 6S subunit by different strategies that were then used to characterize the binding capacity of a panel of anti-RHDV2 MAbs. From the comparison of the results obtained, the biosensor composed of intact RHDV2 captured with catcher-MAb covalently immobilized to the surface showed the best analytical performances. To evaluate the versatility of the biosensor, the same strategy was then adopted using FMVD in cell extracts. The results obtained are discussed in view of the exploitation of SPR in the rapid and resilient fine characterization of antiviral MAbs for diagnostic or therapeutic purposes in the field of animal virology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surface Plasmon ResonanceHemorrhagic Disease Virus, RabbitFoot-and-Mouth Disease VirusAntibodies, MonoclonalAntibodies, ViralBiosensing TechniquesFoot-and-Mouth DiseaseCaliciviridae InfectionsAnimalsRabbitsAntigens, Viral

Stichwörter der Autor:innen

BiosensorsFMDVMonoclonal antibody characterizationRHDVSurface plasmon resonanceVirus detection

Substanzen

Antibodies, MonoclonalAntibodies, ViralAntigens, Viral

Autor:innen und Institutionen

  • Department of Molecular and Translational Medicine, University of Brescia, Brescia, Italy.
  • Istituto Zooprofilattico Sperimentale della Lombardia e dell'Emilia Romagna and WOAH, Reference Laboratory for Rabbit Haemorrhagic Disease, Brescia, Italy.
  • Department of Molecular and Translational Medicine, University of Brescia, Brescia, Italy; Consorzio Interuniversitario Biotecnologie (CIB), Unit of Brescia, Brescia, Italy. Electronic address: marco.rusnati@unibs.it.

Förderung

  • Ministero dell’Istruzione, dell’Università e della Ricerca
  • Ministry of Health

Zitieren

APA

Urbinati, C., Pezzoni, G., Cavadini, P., Giovanni, V. D., Capucci, L., & Rusnati, M. (2025). Validation of plasmonic-based biosensors for rapid and in depth characterization of monoclonal antibodies directed against rabbit haemorrhagic and foot-and-mouth disease viruses in biological samples. Methods. https://doi.org/10.1016/j.ymeth.2024.12.003

Vancouver

Urbinati C, Pezzoni G, Cavadini P, Giovanni VD, Capucci L, Rusnati M. Validation of plasmonic-based biosensors for rapid and in depth characterization of monoclonal antibodies directed against rabbit haemorrhagic and foot-and-mouth disease viruses in biological samples. Methods. 2025. doi:10.1016/j.ymeth.2024.12.003

BibTeX
@article{Urbinati2025,
  author = {Urbinati, Chiara and Pezzoni, Giulia and Cavadini, Patrizia and Giovanni, Vittoria Di and Capucci, Lorenzo and Rusnati, Marco},
  title = {Validation of plasmonic-based biosensors for rapid and in depth characterization of monoclonal antibodies directed against rabbit haemorrhagic and foot-and-mouth disease viruses in biological samples},
  journal = {Methods},
  year = {2025},
  doi = {10.1016/j.ymeth.2024.12.003}
}
Kostenlos starten →