Performance characteristics of obstructive sleep apnea screening instruments in adults with epilepsy
Epilepsy & Behavior · 2026
DOI: 10.1016/j.yebeh.2026.111310 ↗Kurz gefasst
Fachartikel in der Zeitschrift Epilepsy & Behavior, 2026. Verfasst von Jad El Ahdab und 6 weiteren Autor:innen. Beteiligte Einrichtung: Sleep Disorders Center, Department of Neurology, Neurological Institute, Cleveland Clinic, Cleveland, OH, USA. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Epilepsy. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
RATIONALE: Obstructive Sleep Apnea (OSA) is a highly prevalent, but often overlooked comorbidity in adults with epilepsy (AWE). Screening instruments widely used in general populations include STOP (Snoring, Tiredness, Observed apneas, high blood Pressure) and STOP-BANG (+BMI, Age, Neck circumference (NC), and Gender). Novel screens such as STOP-BAG2 may improve OSA risk stratification, but validity and performance characteristics of OSA instruments have not been studied in large AWE populations. METHODS: We analyzed 724 AWE with STOP-BANG data available within 1 year of polysomnography (PSG). The primary outcome was apnea-hypopnea index (AHI) ≥ 5. We compared STOP, STOP-BANG, STOP-BAG, STOP-BAG2, and reweighted STOP-BANG2. Sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve (AUC) were estimated. Instrument performance was compared by differences in AUC, with optimal cutoffs identified by the Youden index and internally validated using 1,000 bootstrap resamples. Seizure severity and frequency were assessed with the Liverpool Seizure Severity Scale. RESULTS: Higher STOP, STOP-BANG, STOP-BAG, and STOP-BAG2 scores were associated with AHI ≥ 5. STOP-BANG, STOP-BAG, STOP-BAG2, and STOP-BANG2 were superior to STOP. STOP-BAG2 and STOP-BANG2 showed the strongest predictive power, each with an AUC of 0.70. At the Youden cutoff, STOP-BAG2 yielded 67 % sensitivity and 65 % specificity, while STOP-BANG2 yielded 72 % sensitivity and 60 % specificity. STOP-BAG2 was superior to STOP-BANG and STOP-BAG (p = 0.003 and p = 0.001, respectively) and did not differ from STOP-BANG2 (p = 0.84). CONCLUSIONS: STOP-derived instruments showed limited-to-moderate discrimination for PSG-defined OSA. The continuous weighted models had the highest AUCs, but the gain over categorical scores was modest, and their selected cutoffs would miss a clinically relevant portion of OSA cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sleep Disorders Center, Department of Neurology, Neurological Institute, Cleveland Clinic, Cleveland, OH, USA.
- Department of Neurology, Neurological Institute, Cleveland Clinic, Cleveland, OH, USA.
- Cleveland Clinic Quantitative Health Sciences, Cleveland, OH, USA.
- Department of Neurology, University of New Mexico, Albuquerque, NM, USA.
- Sleep Disorders Center, Department of Neurology, Neurological Institute, Cleveland Clinic, Cleveland, OH, USA. Electronic address: foldvan@ccf.org.
Zitieren
APA
El Ahdab, J., Bare, T., Araujo, M. L., Bena, J., Ryan, D., Grigg-Damberger, M., & Foldvary-Schaefer, N. (2026). Performance characteristics of obstructive sleep apnea screening instruments in adults with epilepsy. Epilepsy & Behavior. https://doi.org/10.1016/j.yebeh.2026.111310
Vancouver
El Ahdab J, Bare T, Araujo ML, Bena J, Ryan D, Grigg-Damberger M, et al. Performance characteristics of obstructive sleep apnea screening instruments in adults with epilepsy. Epilepsy & Behavior. 2026. doi:10.1016/j.yebeh.2026.111310
BibTeX
@article{ElAhdab2026,
author = {El Ahdab, Jad and Bare, Tyler and Araujo, Matheus Lima and Bena, James and Ryan, Delaney and Grigg-Damberger, Madeleine and Foldvary-Schaefer, Nancy},
title = {Performance characteristics of obstructive sleep apnea screening instruments in adults with epilepsy},
journal = {Epilepsy & Behavior},
year = {2026},
doi = {10.1016/j.yebeh.2026.111310}
}
EUVIMED