Fachartikel in der Zeitschrift Journal of Pharmaceutical Sciences, 2026-06. Verfasst von John F Seeler und 4 weiteren Autor:innen. Beteiligte Einrichtung: Drug Product and Device Development, Takeda Pharmaceutical Company, 200 Shire Way, Lexington, MA, 02421, USA. Hauptthemen laut MEDLINE: Antibodies, Monoclonal, Drug Delivery Systems. Die Arbeit nennt 57 Literaturangaben. Gefördert von: Takeda Pharmaceuticals USA Inc, Takeda Pharmaceutical Company.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The impact of injection time, protein modality and concentration/viscosity during the administration of biologics using closed system transfer devices (CSTDs) on drug product quality was investigated. Three brands of CSTDs with different silicone oil levels and fluid path geometries were used to simulate injections through both IV lines and IV bags using two model proteins (a monoclonal antibody [mAb] and an antibody fusion protein). There was an inverse relationship between visible and subvisible particles levels and injection time regardless of the protein modality and CSTD tested. Data from subvisible particle analyses suggested most particles were silicone oil following rapid injection times. Dynamic light scattering detected proteinaceous aggregates that formed following rapid injections of lower concentrations of the antibody fusion protein but not for the mAb. Computational Fluid Dynamics analysis demonstrated that shorter injection times and higher protein concentration/viscosity of the products increased both interfacial and wall shear stresses, and showed that these stresses differed among brands of CSTD when analyzed at the same injection time and viscosity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Antibodies, MonoclonalDrug Delivery SystemsViscositySilicone OilsTime FactorsHydrodynamicsInjectionsRecombinant Fusion Proteins

Stichwörter der Autor:innen

Antibody drug(s)Drug delivery system(s)FragilityHigh concentrationIn silico modelingPrecipitationProtein aggregationProtein deliveryStability

Substanzen

Antibodies, MonoclonalSilicone OilsRecombinant Fusion Proteins

Autor:innen und Institutionen

  • Drug Product and Device Development, Takeda Pharmaceutical Company, 200 Shire Way, Lexington, MA, 02421, USA.
  • Drug Product and Device Development, Takeda Pharmaceutical Company, 200 Shire Way, Lexington, MA, 02421, USA. Electronic address: yongting.ma@takeda.com.

Förderung

  • Takeda Pharmaceuticals USA Inc
  • Takeda Pharmaceutical Company

Zitieren

APA

Seeler, J. F., Mason, B. D., Swami, V., Salamat-Miller, N., & Ma, Y. (2026). Impact of injection time and protein modality on particle formation when using closed system transfer devices. Journal of Pharmaceutical Sciences, 115(6), 104281. https://doi.org/10.1016/j.xphs.2026.104281

Vancouver

Seeler JF, Mason BD, Swami V, Salamat-Miller N, Ma Y. Impact of injection time and protein modality on particle formation when using closed system transfer devices. Journal of Pharmaceutical Sciences. 2026;115(6):104281. doi:10.1016/j.xphs.2026.104281

BibTeX
@article{Seeler2026,
  author = {Seeler, John F and Mason, Bruce D and Swami, Vish and Salamat-Miller, Nazila and Ma, Yongting},
  title = {Impact of injection time and protein modality on particle formation when using closed system transfer devices},
  journal = {Journal of Pharmaceutical Sciences},
  year = {2026},
  volume = {115},
  number = {6},
  pages = {104281},
  doi = {10.1016/j.xphs.2026.104281}
}
Kostenlos starten →