EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Vial Wall Effect on Freeze-Drying Speed

Matjaž Ramšak, Matjaž Hriberšek

Journal of Pharmaceutical Sciences · 2024

DOI: 10.1016/j.xphs.2023.12.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Pharmaceutical Sciences, 2024. Verfasst von Matjaž Ramšak und 1 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Mechanical Engineering, University of Maribor, Smetanova 17, Maribor SI-2000, Slovenia. Electronic address: matjaz.ramsak@um.si. Hauptthemen laut MEDLINE: Technology, Pharmaceutical, Aluminum. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Public Research Agency of the Republic of Slovenia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The vial wall thermal conductivity and thickness effect on freeze-drying speed is simulated. A 2D axisymmetric numerical simulation of Mannitol freeze-drying is employed using the boundary element method. The originality of the presented approach lies in the simulation of heat transfer in the vial walls as an additional computational domain in contrast to the typical methodology without a vial wall. The numerical model was validated using our measurements and the measurements from the literature. Increasing the glass vial thickness from 1 mm to 2 mm has been found as the major factor in primary drying time, increasing the gravimetrical Kv up to 20 % for all the simulated chamber pressures. The effect of thermal conductivity was simulated using a polymer and aluminium vial replacing the standard glass vial of the same thickness. The polymer vial's decreased Kv value is 5.6 % at a low chamber pressure of 50 mTorr, and 12.2 % at 400 mTorr, which is in excellent agreement with the experiment. Using higher conductivity materials, for example, aluminium, only 3.7 % and 2.3 % Kv increase were computed for low and high chamber pressures respectively.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Technology, PharmaceuticalAluminumFreeze DryingDesiccationHot TemperaturePolymersTemperature

Stichwörter der Autor:innen

Boundary element methodFreeze-dryingLyophilization speedupVial heat conductivityVial wall thickness

Substanzen

AluminumPolymers

Autor:innen und Institutionen

  • Faculty of Mechanical Engineering, University of Maribor, Smetanova 17, Maribor SI-2000, Slovenia. Electronic address: matjaz.ramsak@um.si.
  • Faculty of Mechanical Engineering, University of Maribor, Smetanova 17, Maribor SI-2000, Slovenia.

Förderung

  • Public Research Agency of the Republic of Slovenia

Zitieren

APA

Ramšak, M., & Hriberšek, M. (2024). Vial Wall Effect on Freeze-Drying Speed. Journal of Pharmaceutical Sciences. https://doi.org/10.1016/j.xphs.2023.12.005

Vancouver

Ramšak M, Hriberšek M. Vial Wall Effect on Freeze-Drying Speed. Journal of Pharmaceutical Sciences. 2024. doi:10.1016/j.xphs.2023.12.005

BibTeX
@article{Ramak2024,
  author = {Ramšak, Matjaž and Hriberšek, Matjaž},
  title = {Vial Wall Effect on Freeze-Drying Speed},
  journal = {Journal of Pharmaceutical Sciences},
  year = {2024},
  doi = {10.1016/j.xphs.2023.12.005}
}
Kostenlos starten →