Pointwise Prediction of Pattern Deviation Probability Maps from Wide-Field Volumetric OCT Scans
Ophthalmology Science · 2026-11 · 101462
DOI: 10.1016/j.xops.2026.101462 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmology Science, 2026-11. Verfasst von Deming Wang und 13 weiteren Autor:innen. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Purpose
To develop and evaluate a deep learning (DL) system based on wide-field (WF) volumetric optical coherence tomography (OCT) for pointwise prediction of 24-2 visual field (VF) sensitivity and complete pattern deviation probability (PDP) maps in glaucoma.
Design
Multicenter cross-sectional model development and validation study with prospectively collected external test data.
Participants
A total of 4,055 same-day OCT-VF pairs from 2,552 participants, including glaucoma and non-glaucoma eyes.
Methods
Three-dimensional OCT scans, including WF scans (12×9 mm 2 ) and conventional macula- and disc-centered scans (6×6 mm 2 ), were collected from Zhongshan Ophthalmic Center and TongRen Hospital. Swin Transformer–based DL models were developed using the Zhongshan Ophthalmic Center dataset and externally tested on the TongRen Hospital dataset. Model performance was further evaluated in central versus peripheral VF regions and across glaucoma severity subgroups stratified by mean deviation (MD). Main Outcome Measures Pointwise mean absolute error (MAE) for VF sensitivity prediction, and accuracy, recall, specificity, and F1-score for PDP prediction.
Results
In the internal validation set, the WF-based model achieved the best performance, with an average MAE of 3.31 dB, PDP accuracy of 89.4%, recall of 53.3%, specificity of 95.9%, and F1-score of 60.1%. In the external test set, the WF-based model similarly showed the best performance, with an average MAE of 2.97 dB, PDP accuracy of 88.3%, recall of 48.9%, specificity of 95.2%, and F1-score of 55.6%. The WF-based model outperformed the macula- and disc-based models across the principal performance metrics, with the advantage most evident in peripheral VF regions and becoming more pronounced in moderate and advanced glaucoma.
Conclusions
Wide-field volumetric OCT outperformed conventional 6×6 mm macula- and disc-centered scans for pointwise VF prediction and complete PDP map generation. Broader structural coverage may improve the prediction of peripheral and defect-prone VF locations, particularly in more advanced glaucoma.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Wang, D., Song, D., Yang, Z., Zhou, X., Li, Z., Jiang, J., Kong, K., Jiang, J., Fang, Z., Liu, X., Xie, B., Xu, G., Zhang, X., & Li, F. (2026). Pointwise Prediction of Pattern Deviation Probability Maps from Wide-Field Volumetric OCT Scans. Ophthalmology Science, 101462. https://doi.org/10.1016/j.xops.2026.101462
Vancouver
Wang D, Song D, Yang Z, Zhou X, Li Z, Jiang J, et al. Pointwise Prediction of Pattern Deviation Probability Maps from Wide-Field Volumetric OCT Scans. Ophthalmology Science. 2026:101462. doi:10.1016/j.xops.2026.101462
BibTeX
@article{Wang2026,
author = {Wang, Deming and Song, Diping and Yang, Zefeng and Zhou, Xinrong and Li, Zihan and Jiang, Jiaxuan and Kong, Kangjie and Jiang, Jingwen and Fang, Zige and Liu, Xiaoyi and Xie, Bin and Xu, Guihua and Zhang, Xiulan and Li, Fei},
title = {Pointwise Prediction of Pattern Deviation Probability Maps from Wide-Field Volumetric OCT Scans},
journal = {Ophthalmology Science},
year = {2026},
pages = {101462},
doi = {10.1016/j.xops.2026.101462}
}
EUVIMED