EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Validity and Reliability of the CVI Range for Clinical Research: Baseline and One-Year Results

Melinda Y Chang, Mark W Reid, Christine Roman-Lantzy, Dilshad Contractor, Katherine Granger, Sharon H O'Neil, Francesca Crozier-Fitzgerald, Martha Veto, Mark S Borchert

Ophthalmology Science · 2026-07 · 6 (7) · 101233

DOI: 10.1016/j.xops.2026.101233 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmology Science, 2026-07. Verfasst von Melinda Y Chang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Ophthalmology, The Vision Center at the Children's Hospital Los Angeles, Los Angeles, California. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Knights Templar Eye Foundation, Research to Prevent Blindness, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Cerebral/cortical visual impairment (CVI) is a leading cause of visual impairment in children and significantly impacts both visual function and functional vision (the ability to use vision during everyday activities). We developed the CVI Range for Clinical Research (CVI Range-CR), a functional vision assessment that can be incorporated in CVI clinical trials. Herein we evaluate the psychometric properties, interrater and intrarater reliability, and validity of the CVI Range-CR.

Design

A prospective, longitudinal cohort study.

Participants

Forty children with CVI.

Methods

Participants underwent CVI Range-CR assessments at baseline and 1-year follow-up. All assessments were recorded. A trained in-person examiner scored in-person assessments; 2 expert remote graders scored recorded assessments. Visual acuity was evaluated by a pediatric neuro-ophthalmologist using the 6-level visual behavior scale (VBS). Main Outcome Measures: The CVI Range-CR scores (ranging from 0 to 10) using the Across-CVI Characteristics (rating 1) and Within-CVI Characteristics (rating 2) methods of scoring were compared among graders using the intraclass correlation coefficient (ICC) to assess interrater reliability. A subset of videos was scored twice by the same remote examiner to assess intrarater reliability using the ICC. The CVI Range-CR scores were compared to VBS scores (Spearman's correlation coefficient, ⍴) to evaluate validity. McDonald's ω was used to assess internal consistency of the 10 items on the Within-CVI Characteristics scale.

Results

The CVI Range-CR demonstrated high internal consistency (McDonald's ω = 0.96), excellent intrarater reliability (ICC = 0.88-0.98), good-to-excellent interrater reliability (ICC = 0.74-0.88), and strong correlation to clinical assessment of visual behavior as measured by VBS scores (Spearman's ⍴ = 0.76-0.86, P < 0.0001). It was also sensitive to change; there were small but significant improvements in both ratings 1 and 2 over 1 year (rating 1 average: +0.35, P = 0.002; rating 2 average: +0.31, P = 0.001).

Conclusions

The CVI Range-CR is a reliable and valid measure of functional vision in children with CVI. Because intrarater reliability exceeds interrater reliability, longitudinal studies are recommended to use consistent graders over time. This could be accomplished by remote grading of recorded assessments via a centralized reading center. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Schlagwörter

Stichwörter der Autor:innen

CVI rangeCerebral visual impairmentCortical visual impairmentFunctional vision assessment

Autor:innen und Institutionen

  • Division of Ophthalmology, The Vision Center at the Children's Hospital Los Angeles, Los Angeles, California.
  • Roski Eye Center, University of Southern California, Los Angeles, California.
  • Pediatric View, Children's Home of Pittsburgh, Pittsburgh, Pennsylvania.
  • Division of Neurology, The Saban Research Institute, Children's Hospital Los Angeles, Los Angeles, California.
  • Department of Neurology, University of Southern California, Los Angeles, California.
  • College of Education, University of Georgia, Athens, Georgia.

Förderung

  • Knights Templar Eye Foundation
  • Research to Prevent Blindness
  • National Institutes of Health
  • National Eye Institute

Zitieren

APA

Chang, M. Y., Reid, M. W., Roman-Lantzy, C., Contractor, D., Granger, K., O'Neil, S. H., Crozier-Fitzgerald, F., Veto, M., & Borchert, M. S. (2026). Validity and Reliability of the CVI Range for Clinical Research: Baseline and One-Year Results. Ophthalmology Science, 6(7), 101233. https://doi.org/10.1016/j.xops.2026.101233

Vancouver

Chang MY, Reid MW, Roman-Lantzy C, Contractor D, Granger K, O'Neil SH, et al. Validity and Reliability of the CVI Range for Clinical Research: Baseline and One-Year Results. Ophthalmology Science. 2026;6(7):101233. doi:10.1016/j.xops.2026.101233

BibTeX
@article{Chang2026,
  author = {Chang, Melinda Y and Reid, Mark W and Roman-Lantzy, Christine and Contractor, Dilshad and Granger, Katherine and O'Neil, Sharon H and Crozier-Fitzgerald, Francesca and Veto, Martha and Borchert, Mark S},
  title = {Validity and Reliability of the CVI Range for Clinical Research: Baseline and One-Year Results},
  journal = {Ophthalmology Science},
  year = {2026},
  volume = {6},
  number = {7},
  pages = {101233},
  doi = {10.1016/j.xops.2026.101233}
}
Kostenlos starten →