Implementing a Common Data Model in Ophthalmology: Mapping Structured Electronic Health Record Ophthalmic Examination Data to Standard Vocabularies
Ophthalmology Science · 2025-03 · 5 (2) · 100666
DOI: 10.1016/j.xops.2024.100666 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmology Science, 2025-03. Verfasst von Justin C Quon und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Roski Eye Institute, Keck School of Medicine, University of Southern California, Los Angeles, California. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS, NIH HHS, NLM NIH HHS.
Abstract (Originalsprache)
Objective
To identify and characterize concept coverage gaps of ophthalmology examination data elements within the Cerner Millennium electronic health record (EHR) implementations by the Observational Health Data Sciences and Informatics Observational Medical Outcomes Partnership (OMOP) common data model (CDM).
Design
Analysis of data elements in EHRs. Subjects: Not applicable.
Methods
Source eye examination data elements from the default Cerner Model Experience EHR and a local implementation of the Cerner Millennium EHR were extracted, classified into one of 8 subject categories, and mapped to the semantically closest standard concept in the OMOP CDM. Mappings were categorized as exact, if the data element and OMOP concept represented equivalent information, wider, if the OMOP concept was missing conceptual granularity, narrower, if the OMOP concept introduced excess information, and unmatched, if no standard concept adequately represented the data element. Descriptive statistics and qualitative analysis were used to describe the concept coverage for each subject category. Main Outcome Measures: Concept coverage gaps in 8 ophthalmology subject categories of data elements by the OMOP CDM.
Results
There were 409 and 947 ophthalmology data elements in the default and local Cerner modules, respectively. Of the 409 mappings in the default Cerner module, 25% (n = 102) were exact, 53% (n = 217) were wider, 3% (n = 11) were narrower, and 19% (n = 79) were unmatched. In the local Cerner module, 18% (n = 173) of mappings were exact, 54% (n = 514) were wider, 1% (n = 10) were narrower, and 26% (n = 250) were unmatched. The largest coverage gaps were seen in the local Cerner module under the visual acuity, sensorimotor testing, and refraction categories, with 95%, 95%, and 81% of data elements in each respective category having mappings that were not exact. Concept coverage gaps spanned all 8 categories in both EHR implementations.
Conclusions
Considerable coverage gaps by the OMOP CDM exist in all areas of the ophthalmology examination, which should be addressed to improve the OMOP CDM's effectiveness in ophthalmic research. We identify specific subject categories that may benefit from increased granularity in the OMOP CDM and provide suggestions for facilitating consistency of standard concepts, with the goal of improving data standards in ophthalmology. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Roski Eye Institute, Keck School of Medicine, University of Southern California, Los Angeles, California.
- Division of Ophthalmology Informatics and Data Science, Viterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California San Diego, La Jolla, California.
- Southern California Clinical and Translational Science Institute, Los Angeles, California.
- Wilmer Eye Institute, Johns Hopkins School of Medicine, Baltimore, Maryland.
- Department of Information Technology, Keck Medicine of USC, Los Angeles, California.
Förderung
- NEI NIH HHS
- NIH HHS
- NLM NIH HHS
- NCATS NIH HHS
- National Eye Institute
- National Center for Advancing Translational Sciences
- Research to Prevent Blindness
- National Institutes of Health
Zitieren
APA
Quon, J. C., Long, C. P., Halfpenny, W., Chuang, A., Cai, C. X., Baxter, S. L., Daketi, V., Schmitz, A., Bahroos, N., Xu, B. Y., & Toy, B. C. (2025). Implementing a Common Data Model in Ophthalmology: Mapping Structured Electronic Health Record Ophthalmic Examination Data to Standard Vocabularies. Ophthalmology Science, 5(2), 100666. https://doi.org/10.1016/j.xops.2024.100666
Vancouver
Quon JC, Long CP, Halfpenny W, Chuang A, Cai CX, Baxter SL, et al. Implementing a Common Data Model in Ophthalmology: Mapping Structured Electronic Health Record Ophthalmic Examination Data to Standard Vocabularies. Ophthalmology Science. 2025;5(2):100666. doi:10.1016/j.xops.2024.100666
BibTeX
@article{Quon2025,
author = {Quon, Justin C and Long, Christopher P and Halfpenny, William and Chuang, Amy and Cai, Cindy X and Baxter, Sally L and Daketi, Vamsi and Schmitz, Amanda and Bahroos, Neil and Xu, Benjamin Y and Toy, Brian C},
title = {Implementing a Common Data Model in Ophthalmology: Mapping Structured Electronic Health Record Ophthalmic Examination Data to Standard Vocabularies},
journal = {Ophthalmology Science},
year = {2025},
volume = {5},
number = {2},
pages = {100666},
doi = {10.1016/j.xops.2024.100666}
}
EUVIMED