EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Deep-GA-Net for Accurate and Explainable Detection of Geographic Atrophy on OCT Scans

Amr Elsawy, Tiarnan D L Keenan, Qingyu Chen, Xioashuang Shi, Alisa T Thavikulwat, Sanjeeb Bhandari, Emily Y Chew, Zhiyong Lu

Ophthalmology Science · 2023-12 · 3 (4) · 100311

DOI: 10.1016/j.xops.2023.100311 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmology Science, 2023-12. Verfasst von Amr Elsawy und 7 weiteren Autor:innen. Beteiligte Einrichtung: National Center for Biotechnology Information, National Library of Medicine, National Institutes of Health, Bethesda, Maryland. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Eye Institute, U.S. National Library of Medicine, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To propose Deep-GA-Net, a 3-dimensional (3D) deep learning network with 3D attention layer, for the detection of geographic atrophy (GA) on spectral domain OCT (SD-OCT) scans, explain its decision making, and compare it with existing methods.

Design

Deep learning model development.

Participants

Three hundred eleven participants from the Age-Related Eye Disease Study 2 Ancillary SD-OCT Study.

Methods

A dataset of 1284 SD-OCT scans from 311 participants was used to develop Deep-GA-Net. Cross-validation was used to evaluate Deep-GA-Net, where each testing set contained no participant from the corresponding training set. En face heatmaps and important regions at the B-scan level were used to visualize the outputs of Deep-GA-Net, and 3 ophthalmologists graded the presence or absence of GA in them to assess the explainability (i.e., understandability and interpretability) of its detections. Main Outcome Measures: Accuracy, area under receiver operating characteristic curve (AUC), area under precision-recall curve (APR).

Results

Compared with other networks, Deep-GA-Net achieved the best metrics, with accuracy of 0.93, AUC of 0.94, and APR of 0.91, and received the best gradings of 0.98 and 0.68 on the en face heatmap and B-scan grading tasks, respectively.

Conclusions

Deep-GA-Net was able to detect GA accurately from SD-OCT scans. The visualizations of Deep-GA-Net were more explainable, as suggested by 3 ophthalmologists. The code and pretrained models are publicly available at https://github.com/ncbi/Deep-GA-Net. Financial Disclosures: The author(s) have no proprietary or commercial interest in any materials discussed in this article.

Schlagwörter

Stichwörter der Autor:innen

Deep LearningDetectionExplainabilityGAGeographic atrophyOCT

Autor:innen und Institutionen

  • National Center for Biotechnology Information, National Library of Medicine, National Institutes of Health, Bethesda, Maryland.
  • Division of Epidemiology and Clinical Applications, National Eye Institute, National Institutes of Health, Bethesda, Maryland.
  • Department of Computer Science and Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.

Förderung

  • National Eye Institute
  • U.S. National Library of Medicine
  • National Institutes of Health

Zitieren

APA

Elsawy, A., Keenan, T. D. L., Chen, Q., Shi, X., Thavikulwat, A. T., Bhandari, S., Chew, E. Y., & Lu, Z. (2023). Deep-GA-Net for Accurate and Explainable Detection of Geographic Atrophy on OCT Scans. Ophthalmology Science, 3(4), 100311. https://doi.org/10.1016/j.xops.2023.100311

Vancouver

Elsawy A, Keenan TDL, Chen Q, Shi X, Thavikulwat AT, Bhandari S, et al. Deep-GA-Net for Accurate and Explainable Detection of Geographic Atrophy on OCT Scans. Ophthalmology Science. 2023;3(4):100311. doi:10.1016/j.xops.2023.100311

BibTeX
@article{Elsawy2023,
  author = {Elsawy, Amr and Keenan, Tiarnan D L and Chen, Qingyu and Shi, Xioashuang and Thavikulwat, Alisa T and Bhandari, Sanjeeb and Chew, Emily Y and Lu, Zhiyong},
  title = {Deep-GA-Net for Accurate and Explainable Detection of Geographic Atrophy on OCT Scans},
  journal = {Ophthalmology Science},
  year = {2023},
  volume = {3},
  number = {4},
  pages = {100311},
  doi = {10.1016/j.xops.2023.100311}
}
Kostenlos starten →