Propensity-adjusted 8-year outcomes following bioprosthetic aortic valve replacement: The influence of novel anticalcification technology
JTCVS Open · 2026-02 · 29 · 101557
DOI: 10.1016/j.xjon.2025.101557 ↗Kurz gefasst
Fachartikel in der Zeitschrift JTCVS Open, 2026-02. Verfasst von Tsuyoshi Kaneko und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiothoracic Surgery, Washington University, St Louis, Mo. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Edwards Lifesciences.
Abstract (Originalsprache)
Objective
Aortic bioprostheses with RESILIA (Edwards Lifesciences) tissue technology have demonstrated robust outcomes through 7 years of follow-up. However, studies comparing RESILIA tissue valve outcomes to previous bioprosthetic valves are lacking. We sought to assess surgical aortic valve replacement outcomes in patients implanted with RESILIA tissue valves compared with non-RESILIA valves (PERIMOUNT Magna Ease with ThermaFix treatment; Edwards Lifesciences) at 8 years using data from 2 single-arm trials.
Methods
The analysis consisted of 689 RESILIA patients from the Prospective, Non-Randomized, Multicenter Clinical Evaluation of Edwards Pericardial Bioprostheses With a New Tissue Treatment Platform (COMMENCE) Aortic trial and 258 non-RESILIA surgical aortic valve replacement patients from the Magna Ease postapproval study. To account for differences in baseline characteristics in these cohorts, stabilized inverse probability of treatment weighting with propensity score was used to analyze safety endpoints, including structural valve deterioration (SVD), reoperation due to SVD, all-cause reoperation, and all-cause mortality.
Results
Mean age of the propensity score-adjusted cohort was 67 years, with a majority of male patients. After adjustment, all prespecified clinically relevant baseline variables were appropriately matched. At 8 years, the RESILIA cohort significantly outperformed non-RESILIA valves in freedom from reoperation (97.0% vs 90.5%; P = .0014), reoperation due to SVD (99.2% RESILIA vs 93.9% non-RESILIA; P = .0007), and SVD (99.3% vs 90.5%; P < .0001). Freedom from all-cause mortality was not statistically different between cohorts (83.3% RESILIA vs 81.3% non-RESILIA; P = .6332).
Conclusions
In this propensity-adjusted patient population, surgical aortic valve replacement with this novel tissue treatment was associated with significantly lower rates of SVD, reoperation due to SVD, and all-cause reoperation at 8 years, with similar rates of all-cause mortality.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiothoracic Surgery, Washington University, St Louis, Mo.
- Department of Cardiovascular Surgery, Jefferson Health, Philadelphia, Pa.
- Department of Cardiovascular Surgery, Marcus Valve Center, Piedmont Heart Institute, Atlanta, Ga.
- Division of Cardiac Surgery, Bluhm Cardiovascular Institute at Northwestern Medicine, Chicago, Ill.
Förderung
- Edwards Lifesciences
Zitieren
APA
Kaneko, T., Bavaria, J. E., Thourani, V. H., & Johnston, D. R. (2026). Propensity-adjusted 8-year outcomes following bioprosthetic aortic valve replacement: The influence of novel anticalcification technology. JTCVS Open, 29, 101557. https://doi.org/10.1016/j.xjon.2025.101557
Vancouver
Kaneko T, Bavaria JE, Thourani VH, Johnston DR. Propensity-adjusted 8-year outcomes following bioprosthetic aortic valve replacement: The influence of novel anticalcification technology. JTCVS Open. 2026;29:101557. doi:10.1016/j.xjon.2025.101557
BibTeX
@article{Kaneko2026,
author = {Kaneko, Tsuyoshi and Bavaria, Joseph E and Thourani, Vinod H and Johnston, Douglas R},
title = {Propensity-adjusted 8-year outcomes following bioprosthetic aortic valve replacement: The influence of novel anticalcification technology},
journal = {JTCVS Open},
year = {2026},
volume = {29},
pages = {101557},
doi = {10.1016/j.xjon.2025.101557}
}
EUVIMED