Commercial hybrid graft versus traditional arch replacement with frozen elephant trunk: A multi-institutional comparison
JTCVS Open · 2025-02 · 23 · 19-33
DOI: 10.1016/j.xjon.2024.10.027 ↗Kurz gefasst
Fachartikel in der Zeitschrift JTCVS Open, 2025-02. Verfasst von Markian M Bojko und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, University of Southern California Keck School of Medicine, Los Angeles, Calif. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NCATS NIH HHS.
Abstract (Originalsprache)
Objective
Traditional total arch replacement with frozen elephant trunk requires 2 separate grafts in the descending thoracic aorta and arch, and frequently requires a graft-to-graft anastomosis, which is prone to bleeding. The Thoraflex (Terumo Aortic) device treats the arch and descending thoracic aorta in a single device but has not been compared directly to traditional total arch replacement with frozen elephant trunk and has not been studied in a real-world context in the United States.
Methods
A consecutive sample of total arch replacement with frozen elephant trunk patients across 5 different institutions between January 2018 and January 2024, identified 438 patients of which 83 out of 438 (18.9%) had a Thoraflex device. Propensity score matching in a 1:2 ratio identified 166 well-matched controls. Groups were compared across perioperative outcomes.
Results
One hundred forty out of 438 (32%) patients presented with acute type A dissection, 112 out of 438 (26%) had an aneurysm, and 87 out of 438 (20%) had chronic dissection with a previous proximal repair. One hundred thirty-two out of 438 (30%) underwent surgery on an emergency or emergency/salvage basis. Median (interquartile range [IQR]) crossclamp times in the Thoraflex and traditional matched groups were 71 (IQR, 48-105) and 82 (IQR, 62-123), respectively, (P = .012). Total circulatory arrest times were 19 minutes (IQR, 13-32 minutes) and 23 minutes (IQR, 17-37 minutes), respectively (P = .009). Total procedure times were 6.1 hours (IQR, 5.2-7.3 hours) and 6.8 hours (IQR, 5.7-8.2 hours), respectively (P = .012). The operative mortality, stroke, and paralysis rates were 11 out of 83 (13%), 16 out of 83 (19%), and 4 out of 83 (5%), respectively, in the Thoraflex group and were not significantly different than matched controls.
Conclusions
The Thoraflex hybrid device facilitates shorter crossclamp and circulatory arrest times for arch replacement, with similar observed mortality and stroke rates compared with matched controls.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, University of Southern California Keck School of Medicine, Los Angeles, Calif.
- Department of Surgery, University of Colorado, Denver, Colo.
- Department of Surgery, University of Washington, Seattle, Wash.
- Division of Cardiothoracic Surgery, Providence Sacred Heart Hospital, Spokane, Wash.
- Department of Cardiothoracic Surgery, Hoag Memorial Hospital, Newport Beach, Calif.
- Department of Surgery, University of Utah, Salt Lake City, Utah.
Förderung
- NCATS NIH HHS
Zitieren
APA
Bojko, M. M., Oslund, W., Kirsch, M. J., Carroll, A. M., Longo, E., Clothier, J. S., Okonkwo, K., Rajeev, N., Dhanekula, A., McCarthy, F., Cafarelli, A., Glotzbach, J., Burke, C. R., Reece, T. B., Kobsa, S., & Fleischman, F. (2025). Commercial hybrid graft versus traditional arch replacement with frozen elephant trunk: A multi-institutional comparison. JTCVS Open, 23, 19-33. https://doi.org/10.1016/j.xjon.2024.10.027
Vancouver
Bojko MM, Oslund W, Kirsch MJ, Carroll AM, Longo E, Clothier JS, et al. Commercial hybrid graft versus traditional arch replacement with frozen elephant trunk: A multi-institutional comparison. JTCVS Open. 2025;23:19-33. doi:10.1016/j.xjon.2024.10.027
BibTeX
@article{Bojko2025,
author = {Bojko, Markian M and Oslund, William and Kirsch, Michael J and Carroll, Adam M and Longo, Emma and Clothier, Jessica S and Okonkwo, Kamso and Rajeev, Nithya and Dhanekula, Arjune and McCarthy, Fenton and Cafarelli, Anthony and Glotzbach, Jason and Burke, Christopher R and Reece, T Brett and Kobsa, Serge and Fleischman, Fernando},
title = {Commercial hybrid graft versus traditional arch replacement with frozen elephant trunk: A multi-institutional comparison},
journal = {JTCVS Open},
year = {2025},
volume = {23},
pages = {19--33},
doi = {10.1016/j.xjon.2024.10.027}
}
EUVIMED