Fachartikel in der Zeitschrift JTCVS Open, 2024-10. Verfasst von Mark D Rodefeld und 6 weiteren Autor:innen. Beteiligte Einrichtung: Section of Cardiothoracic Surgery, Department of Surgery, Indiana University School of Medicine and James Whitcomb Riley Hospital for Children, India…. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Children's Heart Foundation, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

After Fontan palliation, patients with single-ventricle physiology are committed to chronic circulatory inefficiency for the duration of their lives. This is due in large part to the lack of a subpulmonary ventricle. A low-pressure rise cavopulmonary assist device can address the subpulmonary deficit and offset the Fontan paradox. We investigated the feasibility of a Fontan pump that is self-powered by tapping reserve pressure energy in the systemic arterial circulation.

Methods

A double-inlet, double-outlet rotary pump was designed to augment Fontan flow through the total cavopulmonary connection. Pump power is supplied by a systemic arterial shunt and radial turbine, with a closed-loop shunt return to the common atrium (QP:QS 1:1). Computational fluid dynamic analysis and lumped parameter modeling of pump impact on the Fontan circulation was performed.

Results

Findings indicate that a pump that can augment all 4 limbs of total cavopulmonary connection flow (superior vena cava/inferior vena cava inflow; left pulmonary artery/right pulmonary artery outflow) using a systemic arterial shunt powered turbine at a predicted cavopulmonary pressure rise of +2.5 mm Hg. Systemic shunt flow is 1.43 lumped parameter model, 22% cardiac output. Systemic venous pressure is reduced by 1.4 mm Hg with improved ventricular preload and cardiac output.

Conclusions

It may be possible to tap reserve pressure energy in the systemic circulation to improve Fontan circulatory efficiency. Further studies are warranted to optimize, fabricate, and test pump designs for hydraulic performance and hemocompatibility. Potential benefits of an autonomous Fontan pump include durable physiologic shift toward biventricular health, freedom from external power, autoregulating function and exercise responsiveness, and improved quality and duration of life.

Schlagwörter

Stichwörter der Autor:innen

Fontan circulationautonomouscavopulmonary assistsubpulmonary pump

Autor:innen und Institutionen

  • Section of Cardiothoracic Surgery, Department of Surgery, Indiana University School of Medicine and James Whitcomb Riley Hospital for Children, Indianapolis, Ind.
  • Department of Bioengineering, Clemson University, Clemson, SC.
  • Rotor Bearing Technology and Software Inc, Phoenixville, Pa.
  • Department of Bioengineering, University of Louisville, Louisville, Ky.
  • Mechanical Solutions Inc, Whippany, NJ.

Förderung

  • Children's Heart Foundation
  • National Institutes of Health

Zitieren

APA

Rodefeld, M. D., Conover, T., Figliola, R., Neary, M., Giridharan, G., Ivashchenko, A., & Bennett, E. M. (2024). Autonomous Fontan pump: Computational feasibility study. JTCVS Open, 21, 257-266. https://doi.org/10.1016/j.xjon.2024.07.003

Vancouver

Rodefeld MD, Conover T, Figliola R, Neary M, Giridharan G, Ivashchenko A, et al. Autonomous Fontan pump: Computational feasibility study. JTCVS Open. 2024;21:257-266. doi:10.1016/j.xjon.2024.07.003

BibTeX
@article{Rodefeld2024,
  author = {Rodefeld, Mark D and Conover, Timothy and Figliola, Richard and Neary, Mike and Giridharan, Guruprasad and Ivashchenko, Artem and Bennett, Edward M},
  title = {Autonomous Fontan pump: Computational feasibility study},
  journal = {JTCVS Open},
  year = {2024},
  volume = {21},
  pages = {257--266},
  doi = {10.1016/j.xjon.2024.07.003}
}
Kostenlos starten →