EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Patient-specific tissue engineered vascular graft for aortic arch reconstruction

Hidenori Hayashi, Jacqueline Contento, Hiroshi Matsushita, Paige Mass, Vincent Cleveland, Seda Aslan, Amartya Dave, Raquel Dos Santos, Angie Zhu, Emmett Reid, Tatsuya Watanabe, Nora Lee und 13 weitere

JTCVS Open · 2024-04 · 18 · 209-220

DOI: 10.1016/j.xjon.2024.02.012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JTCVS Open, 2024-04. Verfasst von Hidenori Hayashi und 24 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiac Surgery, Department of Surgery, University of Chicago, Chicago, Ill. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, NICHD NIH HHS, NIH.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The complexity of aortic arch reconstruction due to diverse 3-dimensional geometrical abnormalities is a major challenge. This study introduces 3-dimensional printed tissue-engineered vascular grafts, which can fit patient-specific dimensions, optimize hemodynamics, exhibit antithrombotic and anti-infective properties, and accommodate growth.

Methods

We procured cardiac magnetic resonance imaging with 4-dimensional flow for native porcine anatomy (n = 10), from which we designed tissue-engineered vascular grafts for the distal aortic arch, 4 weeks before surgery. An optimal shape of the curved vascular graft was designed using computer-aided design informed by computational fluid dynamics analysis. Grafts were manufactured and implanted into the distal aortic arch of porcine models, and postoperative cardiac magnetic resonance imaging data were collected. Pre- and postimplant hemodynamic data and histology were analyzed.

Results

Postoperative magnetic resonance imaging of all pigs with 1:1 ratio of polycaprolactone and poly-L-lactide-co-ε-caprolactone demonstrated no specific dilatation or stenosis of the graft, revealing a positive growth trend in the graft area from the day after surgery to 3 months later, with maintaining a similar shape. The peak wall shear stress of the polycaprolactone/poly-L-lactide-co-ε-caprolactone graft portion did not change significantly between the day after surgery and 3 months later. Immunohistochemistry showed endothelization and smooth muscle layer formation without calcification of the polycaprolactone/poly-L-lactide-co-ε-caprolactone graft.

Conclusions

Our patient-specific polycaprolactone/poly-L-lactide-co-ε-caprolactone tissue-engineered vascular grafts demonstrated optimal anatomical fit maintaining ideal hemodynamics and neotissue formation in a porcine model. This study provides a proof of concept of patient-specific tissue-engineered vascular grafts for aortic arch reconstruction.

Schlagwörter

Stichwörter der Autor:innen

aortic arch reconstructioncomputational fluid dynamicscongenital heart diseasehemodynamicsshape indextissue engineered vascular graftswall shear stress

Autor:innen und Institutionen

  • Division of Cardiac Surgery, Department of Surgery, University of Chicago, Chicago, Ill.
  • Department of Cardiology, Children's National Hospital, Washington, DC.
  • Department of Mechanical Engineering, Johns Hopkins University, Baltimore, Md.
  • Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, Ill.
  • Nanofiber Solutions, LLC, Dublin, Ohio.
  • Division of Vascular Surgery, Department of Surgery, University of Chicago, Chicago, Ill.

Förderung

  • NHLBI NIH HHS
  • NICHD NIH HHS
  • NIH

Zitieren

APA

Hayashi, H., Contento, J., Matsushita, H., Mass, P., Cleveland, V., Aslan, S., Dave, A., Santos, R. D., Zhu, A., Reid, E., Watanabe, T., Lee, N., Dunn, T., Siddiqi, U., Nurminsky, K., Nguyen, V., Kawaji, K., Huddle, J., Pocivavsek, L., …, & Hibino, N. (2024). Patient-specific tissue engineered vascular graft for aortic arch reconstruction. JTCVS Open, 18, 209-220. https://doi.org/10.1016/j.xjon.2024.02.012

Vancouver

Hayashi H, Contento J, Matsushita H, Mass P, Cleveland V, Aslan S, et al. Patient-specific tissue engineered vascular graft for aortic arch reconstruction. JTCVS Open. 2024;18:209-220. doi:10.1016/j.xjon.2024.02.012

BibTeX
@article{Hayashi2024,
  author = {Hayashi, Hidenori and Contento, Jacqueline and Matsushita, Hiroshi and Mass, Paige and Cleveland, Vincent and Aslan, Seda and Dave, Amartya and Santos, Raquel Dos and Zhu, Angie and Reid, Emmett and Watanabe, Tatsuya and Lee, Nora and Dunn, Tyler and Siddiqi, Umar and Nurminsky, Katherine and Nguyen, Vivian and Kawaji, Keigo and Huddle, Joey and Pocivavsek, Luka and Johnson, Jed and Fuge, Mark and Loke, Yue-Hin and Krieger, Axel and Olivieri, Laura and Hibino, Narutoshi},
  title = {Patient-specific tissue engineered vascular graft for aortic arch reconstruction},
  journal = {JTCVS Open},
  year = {2024},
  volume = {18},
  pages = {209--220},
  doi = {10.1016/j.xjon.2024.02.012}
}
Kostenlos starten →