EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Topography-guided ablation for the treatment of irregular astigmatism

Sergio Kwitko, Felipe P. Cabral, Bruno S. de Araújo, Yuri P. Jung

Journal of EuCornea · 2019

DOI: 10.1016/j.xjec.2019.04.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of EuCornea, 2019. Verfasst von Sergio Kwitko und 3 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Refractive surgery promotes good quality of vision without optical correction in most cases. Conventional ablation has reduced effectiveness in irregular corneas, where custom ablations are usually a better option. We have evaluated the results of visual acuity and refraction in patients undergoing custom topography-guided ablation.

Setting

Oftalmocentro, Porto Alegre – RS – Brazil.

Design

This is a case series, retrospective, non-comparative study.

Methods

We studied 60 eyes from 48 patients who underwent topography guided customized refractive surgery, from October 2013 to September 2017, performed with excimer laser Schwind Amaris 750.

Results

Mean age was 44.2 years, being most men (56.6%). Patients with penetrating keratoplasty (PKP) encompassed 36.6% (n = 22), previous radial keratotomy (RK) 20.0% (n = 12), previous deep anterior lamellar keratoplasty (DALK) 16.6% (n = 10) and 26.5% (n = 16) with other diagnoses. Topo-guided surgeries were trans-photorefractive keratectomy (trans-PRK) (41.5%), femto laser-assisted in situ keratomileusis (femto-LASIK) (35.0%), laser-assisted in situ keratomileusis (LASIK) (11.6%) and photorefractive keratectomy (PRK) (11.6%). Cylinder refraction decreased from −3.91 D (±2.00) to −1.45 D (±1.43) (p < 0.01). The spherical equivalent (SE) decreased from −2.04 D (±1.85) to −0.65 D (±1.03) (p < 0.01). Best spectacle-corrected visual acuity (BSCVA) improved in 65% of eyes, from 0.55 (±0.23) to 0.69 (±0.24) (p < 0.01). Follow-up of 40 eyes from 30 patients demonstrated that the effect of the procedure was maintained during the studied period (24,45 ± 14,14 months).

Conclusion

Topography-guided ablation is safe and effective in reducing corneal irregularities, leading to an improvement in visual acuity in 2/3 of cases.

Zitieren

APA

Kwitko, S., Cabral, F. P., Araújo, B. S. D., & Jung, Y. P. (2019). Topography-guided ablation for the treatment of irregular astigmatism. Journal of EuCornea. https://doi.org/10.1016/j.xjec.2019.04.001

Vancouver

Kwitko S, Cabral FP, Araújo BSD, Jung YP. Topography-guided ablation for the treatment of irregular astigmatism. Journal of EuCornea. 2019. doi:10.1016/j.xjec.2019.04.001

BibTeX
@article{Kwitko2019,
  author = {Kwitko, Sergio and Cabral, Felipe P. and Araújo, Bruno S. de and Jung, Yuri P.},
  title = {Topography-guided ablation for the treatment of irregular astigmatism},
  journal = {Journal of EuCornea},
  year = {2019},
  doi = {10.1016/j.xjec.2019.04.001}
}
Kostenlos starten →