EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Corneal incision width after lens implantation: Comparing delivery systems

Carlo Cagini, Maria Teresa Perri, Anna Pia Di Napoli, Tito Fiore, Marco Messina, Leopoldo Spadea, Gian Maria Cavallini

Journal of EuCornea · 2018

DOI: 10.1016/j.xjec.2018.04.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of EuCornea, 2018. Verfasst von Carlo Cagini und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare corneal incision width after phacoemulsification and intraocular lens implantation (IOL) using different delivery systems.

Methods

One hundred and seventeen patients with cataract and no other anterior segment pathological features or previous eye surgery underwent cataract surgery with IOL implantation through a 2.2 mm incision. Three foldable IOL were implanted with their recommended delivery systems: Acrysof© SN60WF with Monarch© III/cartridge D (Group A, 38 patients); Tecnis© ZCB00 with Unfolder Platinum/cartridge easy load (Group B, 38 patients); Acrysof© SN60WF with Ultrasert™ preloaded system (Group C, 42 patients). Incision width was measured before and after phacoemulsification and IOL implantation.

Results

Before and after phacoemulsification incision width was, respectively, 2.21 ± 0.02 mm and 2.34 ± 0.08 mm in group A; 2.20 ± 0.02 mm and 2.31 ± 0.06 mm in group B; 2.20 ± 0.02 mm and 2.30 ± 0.07 mm in group C. Incision width was not significantly enlarged after phacoemulsification. Before and after IOL implantation incision width was, respectively, 2.34 ± 0.07 mm and 2.47 ± 0.07 mm in group A; 2.32 ± 0.06 mm and 2.45 ± 0.08 mm in group B; 2.30 ± 0.07 mm and 2.39 ± 0.07 mm in group C. Incision widths in group C were significantly different to groups A and B. No relationship was found between incision sizes and phacoemulsification time, ultrasound energy and IOL powers.

Conclusion

In cataract surgery Ultrasert™ enlarges the corneal incision less than other delivery systems.

Zitieren

APA

Cagini, C., Perri, M. T., Napoli, A. P. D., Fiore, T., Messina, M., Spadea, L., & Cavallini, G. M. (2018). Corneal incision width after lens implantation: Comparing delivery systems. Journal of EuCornea. https://doi.org/10.1016/j.xjec.2018.04.001

Vancouver

Cagini C, Perri MT, Napoli APD, Fiore T, Messina M, Spadea L, et al. Corneal incision width after lens implantation: Comparing delivery systems. Journal of EuCornea. 2018. doi:10.1016/j.xjec.2018.04.001