Corneal incision width after lens implantation: Comparing delivery systems
Journal of EuCornea · 2018
DOI: 10.1016/j.xjec.2018.04.001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of EuCornea, 2018. Verfasst von Carlo Cagini und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
To compare corneal incision width after phacoemulsification and intraocular lens implantation (IOL) using different delivery systems.
Methods
One hundred and seventeen patients with cataract and no other anterior segment pathological features or previous eye surgery underwent cataract surgery with IOL implantation through a 2.2 mm incision. Three foldable IOL were implanted with their recommended delivery systems: Acrysof© SN60WF with Monarch© III/cartridge D (Group A, 38 patients); Tecnis© ZCB00 with Unfolder Platinum/cartridge easy load (Group B, 38 patients); Acrysof© SN60WF with Ultrasert™ preloaded system (Group C, 42 patients). Incision width was measured before and after phacoemulsification and IOL implantation.
Results
Before and after phacoemulsification incision width was, respectively, 2.21 ± 0.02 mm and 2.34 ± 0.08 mm in group A; 2.20 ± 0.02 mm and 2.31 ± 0.06 mm in group B; 2.20 ± 0.02 mm and 2.30 ± 0.07 mm in group C. Incision width was not significantly enlarged after phacoemulsification. Before and after IOL implantation incision width was, respectively, 2.34 ± 0.07 mm and 2.47 ± 0.07 mm in group A; 2.32 ± 0.06 mm and 2.45 ± 0.08 mm in group B; 2.30 ± 0.07 mm and 2.39 ± 0.07 mm in group C. Incision widths in group C were significantly different to groups A and B. No relationship was found between incision sizes and phacoemulsification time, ultrasound energy and IOL powers.
Conclusion
In cataract surgery Ultrasert™ enlarges the corneal incision less than other delivery systems.
Zitieren
APA
Cagini, C., Perri, M. T., Napoli, A. P. D., Fiore, T., Messina, M., Spadea, L., & Cavallini, G. M. (2018). Corneal incision width after lens implantation: Comparing delivery systems. Journal of EuCornea. https://doi.org/10.1016/j.xjec.2018.04.001
Vancouver
Cagini C, Perri MT, Napoli APD, Fiore T, Messina M, Spadea L, et al. Corneal incision width after lens implantation: Comparing delivery systems. Journal of EuCornea. 2018. doi:10.1016/j.xjec.2018.04.001
BibTeX
@article{Cagini2018,
author = {Cagini, Carlo and Perri, Maria Teresa and Napoli, Anna Pia Di and Fiore, Tito and Messina, Marco and Spadea, Leopoldo and Cavallini, Gian Maria},
title = {Corneal incision width after lens implantation: Comparing delivery systems},
journal = {Journal of EuCornea},
year = {2018},
doi = {10.1016/j.xjec.2018.04.001}
}
EUVIMED