Head Mounted Three-Dimensional High-Definition Display System for Microscopic Surgical Field Observation: An Observational Study

Yohei Nounaka, Fumihiro Matano, Katsuya Umeoka, Asami Kubota, Narumi Matsumoto, Tadashi Higuchi, Hiroki Umezawa, Takeshi Matsunobu, Takao Kitamura, Yutaka Igarashi, Ryuta Nakae, Shoji Yokobori und 1 weitere

World Neurosurgery · 2025

DOI: 10.1016/j.wneu.2025.124256 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift World Neurosurgery, 2025. Verfasst von Yohei Nounaka und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurological Surgery, Nippon Medical School Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Microsurgery, Imaging, Three-Dimensional, Neurosurgical Procedures. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Microscopic surgery poses ergonomic challenges due to the constraints of fixed eyepieces. While monitor-based exoscopes offer alternatives, they may limit immersion and assistant visibility. Head-mounted displays (HMDs) have proposed these constraints. This study evaluated the technical capabilities of a three-dimensional high-definition HMD system during surgical simulation to determine its usability compared with conventional and exoscopic visualization methods. METHODS: Thirty-five physicians and residents with varying microsurgical experience evaluated 3 visualization methods: HMD, conventional microscope eyepieces, and a 55″ exoscopic monitor. The evaluation criteria included resolution, immersion, depth perception, ergonomic comfort, peripheral vision, and visual latency. We also measured the effective latency times. RESULTS: HMD ranked between the microscope and exoscope across all evaluation criteria. The microscope was rated highest in resolution, immersion, depth perception, and visual latency. Surgeons with >5 years of practice rated HMD higher than microscopes for ergonomics (P = 0.029) and peripheral vision (P = 0.009). The measured image latency was approximately 0.093 ± 0.0018 s. Finally, the HMD system showed better operator and assistant participation. CONCLUSIONS: While the HMD showed potential for ergonomic benefit and enhanced peripheral engagement, further development is needed, particularly regarding image quality, and magnification. Given that clinical integration in this preliminary study was limited to observation; further development is needed, including larger numbers of cases and diverse operative settings, including primary surgeons, assistants, scrub nurses, and surgical observers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrosurgeryImaging, Three-DimensionalNeurosurgical ProceduresHumansErgonomicsMaleFemaleMicroscopyAdult

Stichwörter der Autor:innen

ErgonomicsExoscopeHead mounted displayMicroscopeMicrosurger

Autor:innen und Institutionen

  • Department of Neurological Surgery, Nippon Medical School Hospital, Tokyo, Japan.
  • Department of Plastic, Reconstructive, Aesthetic Surgery, Nippon Medical School Hospital, Tokyo, Japan.
  • Department of Otorhinolaryngology, Head and Neck Surgery, Nippon Medical School Hospital, Tokyo, Japan.
  • Department of Emergency and Critical Care Medicine, Nippon Medical School Hospital, Tokyo, Japan.
  • Department of Neurological Surgery, Nippon Medical School Hospital, Tokyo, Japan. Electronic address: ymurai@nms.ac.jp.

Zitieren

APA

Nounaka, Y., Matano, F., Umeoka, K., Kubota, A., Matsumoto, N., Higuchi, T., Umezawa, H., Matsunobu, T., Kitamura, T., Igarashi, Y., Nakae, R., Yokobori, S., & Murai, Y. (2025). Head Mounted Three-Dimensional High-Definition Display System for Microscopic Surgical Field Observation: An Observational Study. World Neurosurgery. https://doi.org/10.1016/j.wneu.2025.124256

Vancouver

Nounaka Y, Matano F, Umeoka K, Kubota A, Matsumoto N, Higuchi T, et al. Head Mounted Three-Dimensional High-Definition Display System for Microscopic Surgical Field Observation: An Observational Study. World Neurosurgery. 2025. doi:10.1016/j.wneu.2025.124256

BibTeX
@article{Nounaka2025,
  author = {Nounaka, Yohei and Matano, Fumihiro and Umeoka, Katsuya and Kubota, Asami and Matsumoto, Narumi and Higuchi, Tadashi and Umezawa, Hiroki and Matsunobu, Takeshi and Kitamura, Takao and Igarashi, Yutaka and Nakae, Ryuta and Yokobori, Shoji and Murai, Yasuo},
  title = {Head Mounted Three-Dimensional High-Definition Display System for Microscopic Surgical Field Observation: An Observational Study},
  journal = {World Neurosurgery},
  year = {2025},
  doi = {10.1016/j.wneu.2025.124256}
}
Kostenlos starten →