Risk Factors for Hemodynamic Depression After Carotid Stenting
World Neurosurgery · 2025
DOI: 10.1016/j.wneu.2025.123790 ↗Kurz gefasst
Fachartikel in der Zeitschrift World Neurosurgery, 2025. Verfasst von Yaoliang Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China. Hauptthemen laut MEDLINE: Stents, Carotid Stenosis, Hemodynamics, Postoperative Complications. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Depression
Abstract (Originalsprache)
BACKGROUND: The effects of different stents and morphology of the stenosis on hemodynamic depression (HD) and in-stent restenosis (ISR) are unclear after carotid artery stenting. METHODS: 142 patients were retrospectively enrolled and stratified into straight stent and tapered stent (TS), and further stratified according to stenosis morphology to compare the differences in final events. Logistic analysis was used to determine the risk factors for the occurrence of HD. RESULTS: TS had a lower incidence of postprocedural HD (38.8% vs. 60.0%; P = 0.012) and 1-year ISR (1.5% vs. 8.0%; P = 0.078). In centripetal stenosis, there was no significant difference in postprocedural HD between the different stents (27.3% vs. 47.8%; P = 0.155). In contrast, for eccentric stenosis, TS was associated with a reduced risk of postprocedural HD (42.2% vs. 67.3%; P = 0.013). Logistic analyses found that eccentric stenosis (odds ratio [OR] = 2.561; 95% confidence interval [CI] = 1.100-5.965; P = 0.029), high-echo plaque (OR = 5.877; 95% CI = 1.472-23.462; P = 0.012), open-cell stent (OR = 3.173; 95% CI = 1.067-9.436; P = 0.038), and distal diameter of stent (OR = 1.541; 95% CI = 1.104-2.153; P = 0.011) were risk factors for postprocedural HD. The following factors were identified as risk factors for persistent hemodynamic depression: high-echo plaque (OR = 7.605; 95% CI = 2.105-27.468; P = 0.002) and open-cell stent (OR = 7.017; 95% CI = 1.384-35.583; P = 0.019); additionally, the further the minimum lumen distance from the carotid bifurcation, the lower the risk of persistent hemodynamic depression (OR = 0.942; 95% CI = 0.894-0.992; P = 0.024). CONCLUSIONS: TS reduces the risk of postoperative HD and there is a trend toward a lower risk of ISR at 1 year after the procedure. Eccentric stenosis, high-echo plaque, open-cell stent, and distal diameter of stent are high-risk factors for HD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
- Department of Ultrasound Diagnostics, Tangdu Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
- Department of Vascular Surgery, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China.
- Department of Neurosurgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China. Electronic address: guoqd1991@sina.cn.
Zitieren
APA
Wang, Y., Liu, W., Zhang, Y., Mou, K., Wang, W., Shao, X., Wang, Q., Yang, L., & Guo, Q. (2025). Risk Factors for Hemodynamic Depression After Carotid Stenting. World Neurosurgery. https://doi.org/10.1016/j.wneu.2025.123790
Vancouver
Wang Y, Liu W, Zhang Y, Mou K, Wang W, Shao X, et al. Risk Factors for Hemodynamic Depression After Carotid Stenting. World Neurosurgery. 2025. doi:10.1016/j.wneu.2025.123790
BibTeX
@article{Wang2025,
author = {Wang, Yaoliang and Liu, Wei and Zhang, Yile and Mou, Ke and Wang, Weizhong and Shao, Xiaodong and Wang, Qianliang and Yang, Lin and Guo, Qingdong},
title = {Risk Factors for Hemodynamic Depression After Carotid Stenting},
journal = {World Neurosurgery},
year = {2025},
doi = {10.1016/j.wneu.2025.123790}
}
EUVIMED