Use of Compressed Sensing Accelerated, Low-Velocity Encoded, Isotropic Resolution, Phase Contrast Magnetic Resonance Angiography for SEEG Electrode Implantation
World Neurosurgery · 2024
DOI: 10.1016/j.wneu.2023.02.030 ↗Kurz gefasst
Fachartikel in der Zeitschrift World Neurosurgery, 2024. Verfasst von Qiangqiang Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Neuroscience Center Comprehensive Epilepsy Unit, Department of Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medici…. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Tomography, X-Ray Computed. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Science and Technology Commission of Shanghai Municipality, Shanghai Jiao Tong University.
Abstract (Originalsprache)
OBJECTIVE: We assessed the feasibility of using compressed sensing accelerated, low-velocity encoded, isotropic resolution phase contrast (CLIP) magnetic resonance angiography (MRA) for avascular trajectory planning of stereoelectroencephalography. METHODS: Ten healthy subjects (1 woman and 9 men; age, 33.6 ± 9.0 years) and 20 consecutive patients (12 female patients; age, 22 ± 13.6 years) were enrolled in the present study. The healthy subjects underwent CLIP-MRA, and 3 other phase contrast MRA protocols with conventional parallel imaging (PI) acceleration, including low resolution with twofold PI (PI2), high resolution (HR) with fivefold PI (PI5), and HR-PI2. The patients underwent CLIP-MRA and computed tomography angiography (CTA). The image qualities were evaluated. The numbers and locations of trajectory-vessel conflict detected using CLIP-MRA were noted. RESULTS: With similar scan durations, CLIP-MRA achieved higher spatial resolution compared with low resolution with PI2 and detected significantly more branches compared with HR-PI5. With the same spatial resolution, the signal/noise and contrast/noise ratios of CLIP-MRA were higher than those with HR-PI2 with a shorter scan duration. For the 12 adult patients (10 female patients; 28.8 ± 12.7 years), CLIP-MRA had better signal/noise and contrast/noise ratios than CTA. The trajectory had required modification for 14 of the 20 patients (70%), with a proportion of trajectory modification of 10.7% (23 of 215 electrodes). The middle meningeal artery, cortical vessel, and skull vessel were the main vessels with conflict (n = 11, n = 7, and n = 5, respectively). CONCLUSIONS: In the present study, CLIP-MRA provided a clear cortical vascular display noninvasively without intravascular contrast and radiation. The middle meningeal artery and diploic and emissary veins were the main conflict vessels and could be clearly displayed using CLIP-MRA but not CTA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Clinical Neuroscience Center Comprehensive Epilepsy Unit, Department of Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China; Clinical Neuroscience Center…
- United Imaging Healthcare Group, Shanghai, People's Republic of China.
- Department of Radiology, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.
- Wuhan United Imaging Healthcare Surgical Technology Co., Ltd., Wuhan, People's Republic of China.
- Department of Neurosurgery, Center for Functional Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.
- Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.
Förderung
- Science and Technology Commission of Shanghai Municipality
- Shanghai Jiao Tong University
Zitieren
APA
Liu, Q., Lin, Z., Shen, Y., Zhu, J., Song, J., Zhang, C., Lu, Y., & Xu, J. (2024). Use of Compressed Sensing Accelerated, Low-Velocity Encoded, Isotropic Resolution, Phase Contrast Magnetic Resonance Angiography for SEEG Electrode Implantation. World Neurosurgery. https://doi.org/10.1016/j.wneu.2023.02.030
Vancouver
Liu Q, Lin Z, Shen Y, Zhu J, Song J, Zhang C, et al. Use of Compressed Sensing Accelerated, Low-Velocity Encoded, Isotropic Resolution, Phase Contrast Magnetic Resonance Angiography for SEEG Electrode Implantation. World Neurosurgery. 2024. doi:10.1016/j.wneu.2023.02.030
BibTeX
@article{Liu2024,
author = {Liu, Qiangqiang and Lin, Zengping and Shen, Yiwen and Zhu, Jiachen and Song, Jian and Zhang, Chencheng and Lu, Yong and Xu, Jiwen},
title = {Use of Compressed Sensing Accelerated, Low-Velocity Encoded, Isotropic Resolution, Phase Contrast Magnetic Resonance Angiography for SEEG Electrode Implantation},
journal = {World Neurosurgery},
year = {2024},
doi = {10.1016/j.wneu.2023.02.030}
}
EUVIMED