Immediate hemodynamic effects of transcatheter aortic valve replacement on left ventricular stroke volume and carotid artery blood flow
WFUMB Ultrasound Open · 2023
DOI: 10.1016/j.wfumbo.2023.100008 ↗Kurz gefasst
Fachartikel in der Zeitschrift WFUMB Ultrasound Open, 2023. Verfasst von Joris van Houte und 6 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Themen: Schlaganfall
Abstract (Originalsprache)
Transcatheter aortic valve replacement (TAVR) is performed in selected patients with severe aortic valve stenosis, leading to immediate relief of left ventricular outflow obstruction. The purpose of this study was to evaluate the immediate hemodynamic effects of TAVR on left ventricular stroke volume (SVLVOT) and common carotid artery stroke volume (SVCCA). Twenty-five TAVR patients were included in this prospective observational study. Patients were treated under either local, or general anesthesia. Echocardiographic, and carotid ultrasound measurements were performed in the operating room pre (T1), and post (T2) TAVR. Changes in SVLVOT, SVCCA, carotid peak systolic velocity (PSV), pulsatility index (PI) and other carotid Doppler parameters were evaluated. Following TAVR, the aortic valve area (AVA) increased from 0.8 [0.6–0.9] to 1.9 [1.6–2.3] cm2 (p < 0.001), and the peak transvalvular gradient (PGAV) decreased from 70 [65–81] to 15 [11-18] mm Hg (p < 0.001) from T1 to T2. SVLVOT increased from 58 ± 17 to 69 ± 24 ml, p < 0.01, whereas SVCCA remained unchanged (from 10 [7-11] to 10 [8-11] ml, p = 0.50). Δ SVLVOT was 19 [7–31] % and Δ SVCCA was 1 [-7-20] %, p < 0.05. PSV increased from 68 ± 17 to 81 ± 17 cm/s, p < 0.001, and PI increased from 1.7 [1.5–2.2] to 2.2 [1.7–2.6], p < 0.001. Successful TAVR resulted in immediate improvement of left ventricular stroke volume, whereas carotid stroke volume remained unchanged.
Zitieren
APA
Houte, J. V., Eerdekens, R., Dieters, E., Pas, M. T., Wijnbergen, I., Tonino, P., & Bouwman, A. (2023). Immediate hemodynamic effects of transcatheter aortic valve replacement on left ventricular stroke volume and carotid artery blood flow. WFUMB Ultrasound Open. https://doi.org/10.1016/j.wfumbo.2023.100008
Vancouver
Houte JV, Eerdekens R, Dieters E, Pas MT, Wijnbergen I, Tonino P, et al. Immediate hemodynamic effects of transcatheter aortic valve replacement on left ventricular stroke volume and carotid artery blood flow. WFUMB Ultrasound Open. 2023. doi:10.1016/j.wfumbo.2023.100008
BibTeX
@article{Houte2023,
author = {Houte, Joris van and Eerdekens, Rob and Dieters, Erik and Pas, Mariska te and Wijnbergen, Inge and Tonino, Pim and Bouwman, Arthur},
title = {Immediate hemodynamic effects of transcatheter aortic valve replacement on left ventricular stroke volume and carotid artery blood flow},
journal = {WFUMB Ultrasound Open},
year = {2023},
doi = {10.1016/j.wfumbo.2023.100008}
}
EUVIMED